171 110

Learning-based catheter and guidewire-driven autonomous vascular intervention robotic system for reduced repulsive force

Title
Learning-based catheter and guidewire-driven autonomous vascular intervention robotic system for reduced repulsive force
Other Titles
Learning-based catheter and guidewire-driven autonomous vascular intervention robotic system for reduced repulsive force
Author
이병주
Keywords
reinforcement learning; supervised learning; vascular intervention; autonomous system; surgical robot
Issue Date
2022-09
Publisher
OXFORD UNIV PRESS
Citation
JOURNAL OF COMPUTATIONAL DESIGN AND ENGINEERING, v. 9, NO. 5, Page. 1549-1564
Abstract
Manual vascular interventional radiology (VIR) procedures have been performed under radiation exposure conditions, and many commercial master-slave VIR robot systems have recently been developed to overcome this issue. However, master-slave VIR robot systems still have limitations. The operator must reside near the master device and control the slave robot using only the master device. In addition, the operator must simultaneously process the recognition of the surgical tool from the X-ray image while operating the master device. To overcome the limitations of master-slave VIR robot systems, we propose an autonomous VIR robot system with a deep learning algorithm that excludes the master device. The proposed autonomous VIR robot with a deep learning algorithm drives surgical tools to the target blood vessel location while simultaneously performing surgical tool recognition. The proposed autonomous VIR robot system detects the location of the surgical tool based on a supervised learning algorithm, and controls the surgical tools based on a reinforcement-learning algorithm. Experiments are conducted using two types of vascular phantoms to verify the effectiveness of the proposed autonomous VIR robot system. The experimental results of the vascular phantom show a comparison between the master-slave VIR robot system and the proposed autonomous VIR robot system in terms of the repulsive force, task completion time, and success rate during the operation. The proposed autonomous VIR robot system is shown to exhibit a significant reduction in repulsive force and a 96% success ratio based on a vascular phantom.
URI
https://academic.oup.com/jcde/article/9/5/1549/6652902https://repository.hanyang.ac.kr/handle/20.500.11754/180996
ISSN
2288-4300;2288-5048
DOI
10.1093/jcde/qwac074
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
96781_이병주.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE