225 0

Influence of void on image quality of industrial SPECT

Title
Influence of void on image quality of industrial SPECT
Author
김찬형
Keywords
Gamma camera; SPECT; PET PET/CT; coronary CT angiography (CTA); Inspection with gamma rays
Issue Date
2013-12
Publisher
IOP PUBLISHING LTD, TEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND
Citation
Journal of Instrumentation, Vol.8, No.12 [2013], p1-8
Abstract
Industrial single photon emission computed tomography (SPECT) is a promising technique to determine the dynamic behavior of industrial process media and has been developed in the Korea Atomic Energy Research Institute. The present study evaluated the influence of a void, which is presence in multiphase reactors of industrial process, on the image quality of an industrial SPECT. The results are very encouraging; that is, the performance of the industrial SPECT system is little influenced by the presence of a void, which means that industrial SPECT is an appropriate tool to estimate the dynamic characteristics of the process media in a water-air phase bubble column with a static gas sparger.