369 0

여름철 플러쉬아웃 시행 시 제습 에너지비용에 관한 연구

Title
여름철 플러쉬아웃 시행 시 제습 에너지비용에 관한 연구
Other Titles
A Study on Energy Cost for Dehumidification on Performing Flush-out in Summer
Author
박준석
Keywords
플러쉬아웃; 제습; 에너지비용; 빌트인 가전제품; 실내공기질; Flush-out; Dehumidification; Energy Cost; Built-in Home Appliances; IAQ
Issue Date
2016-04
Publisher
대한건축학회
Citation
대한건축학회 춘계학술발표대회 논문집, v. 36, NO 1(통권 제64집), Page. 223-224
Abstract
Newly constructed multi-residential buildings should be flushed out indoor contaminants after the completion of construction and prior to the occupancy by the Heath-friendly Housing Construction Standards. The flush-out performing standard recommends to maintain indoor relative humidity below 60% during the performing flush-out but it is hard to maintain recommended relative humidity because the weather of korea is a high humidity in summer. The scale of the domestic market being expanded not only built-in home appliance but also dehumidifier for a comfortable indoor environment in present. Therefore, this study calculate energy cost for dehumidification as calculated dehumidification performance by condition of performing flush-out when the flush-out performed by using dehumidifier. As a result, the amount of dehumidification for performing flush-out was estimated as maximum 20.5L/Day in Incheon City, and 19.4L/Day in Gwangju City. And it was also found that performing flush-out was lowest energy cost at 0.5ACH(14Days) than other air change rate.
URI
http://www.aik.or.kr/html/page04_04_list.jsp?ncode=p002hhttp://www.dbpia.co.kr/Journal/ArticleDetail/NODE06651063http://hdl.handle.net/20.500.11754/41541
ISSN
2287-5786
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE