Full metadata record

DC FieldValueLanguage
dc.contributor.author박준석-
dc.date.accessioned2018-03-02T07:22:07Z-
dc.date.available2018-03-02T07:22:07Z-
dc.date.issued2016-04-
dc.identifier.citation대한건축학회 춘계학술발표대회 논문집, v. 36, NO 1(통권 제64집), Page. 223-224en_US
dc.identifier.issn2287-5786-
dc.identifier.urihttp://www.aik.or.kr/html/page04_04_list.jsp?ncode=p002h-
dc.identifier.urihttp://www.dbpia.co.kr/Journal/ArticleDetail/NODE06651063-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/41541-
dc.description.abstractNewly constructed multi-residential buildings should be flushed out indoor contaminants after the completion of construction and prior to the occupancy by the Heath-friendly Housing Construction Standards. The flush-out performing standard recommends to maintain indoor relative humidity below 60% during the performing flush-out but it is hard to maintain recommended relative humidity because the weather of korea is a high humidity in summer. The scale of the domestic market being expanded not only built-in home appliance but also dehumidifier for a comfortable indoor environment in present. Therefore, this study calculate energy cost for dehumidification as calculated dehumidification performance by condition of performing flush-out when the flush-out performed by using dehumidifier. As a result, the amount of dehumidification for performing flush-out was estimated as maximum 20.5L/Day in Incheon City, and 19.4L/Day in Gwangju City. And it was also found that performing flush-out was lowest energy cost at 0.5ACH(14Days) than other air change rate.en_US
dc.description.sponsorship이 연구는 2016년도 국토교통부 주거환경연구사업의 연구비지원에 의한 결과의 일부임. 과제번호: 16RERP-B082204-03en_US
dc.language.isoko_KRen_US
dc.publisher대한건축학회en_US
dc.subject플러쉬아웃en_US
dc.subject제습en_US
dc.subject에너지비용en_US
dc.subject빌트인 가전제품en_US
dc.subject실내공기질en_US
dc.subjectFlush-outen_US
dc.subjectDehumidificationen_US
dc.subjectEnergy Costen_US
dc.subjectBuilt-in Home Appliancesen_US
dc.subjectIAQen_US
dc.title여름철 플러쉬아웃 시행 시 제습 에너지비용에 관한 연구en_US
dc.title.alternativeA Study on Energy Cost for Dehumidification on Performing Flush-out in Summeren_US
dc.typeArticleen_US
dc.relation.page223-224-
dc.relation.journal대한건축학회논문집 계획계-
dc.contributor.googleauthor이기용-
dc.contributor.googleauthor김주한-
dc.contributor.googleauthor박준석-
dc.contributor.googleauthorLee, Ki Yong-
dc.contributor.googleauthorKim, Joo Han-
dc.contributor.googleauthorPark, Jun-Seok-
dc.relation.code2016018720-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjunpark-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE