160 0

Simultaneous assessment of organophosphate flame retardants, plasticizers, trace metals, and house dust mite allergens in settled house dust

Title
Simultaneous assessment of organophosphate flame retardants, plasticizers, trace metals, and house dust mite allergens in settled house dust
Author
문효방
Keywords
alternative; house dust mite allergens; OPFR; plasticizer; settled house dust
Issue Date
2022-07
Publisher
WILEY
Citation
INDOOR AIR, v. 32, NO. 7, article no. e13071, Page. 1.0-15.0
Abstract
Settled house dust (SHD) is a reservoir for various contaminants, including endocrine-disrupting chemicals (EDCs), trace metals, and house dust mite allergens. This study aimed to characterize various chemical and biological contaminants in SHD and identify determinants governing the indoor contaminants. In total, 106 SHD samples were collected from 106 houses in Seoul and Gyeonggi Province, Korea, in 2021. Bedding dust samples were collected from 30 of these 106 houses. All participants completed a questionnaire comprised of housing and lifestyle-related factors. The samples were analyzed for 18 organophosphate flame retardants (OPFRs), 16 phthalates, five alternative plasticizers (APs), seven trace metals, and two house dust mite allergens (Dermatophagoides farinae type 1 [Der f1] and Dermatophagoides pteronyssinus type 1 [Der p1]). A multiple regression analysis was conducted to identify the determinants governing the concentrations and profiles of various contaminants. OPFRs, phthalates, APs, and trace metals were detected in all SHD samples, indicating ubiquitous contamination in indoor environments. Among the three EDC groups, APs were detected at the highest concentrations (geometric mean [GM] (geometric standard deviation, [GSD]): 1452 (1.6) mu g/g in total), followed by phthalates (GM (GSD): 676 (1.4) mu g/g in total) and OPFRs (GM (GSD): 10 (1.4) mu g/g in total). Der f1 was detected in all bedding dust samples with significantly higher levels than Der p1 (GM (GSD): 0.1 (1.8) mu g/g vs. 1.4 x 10(-3) (2.3) mu g/g). The concentrations of OPFRs, plasticizers, and trace metals in SHD were significantly associated with the type and number of electronic appliances and combustion activities. Der f1 was significantly associated with the number of occupants and water penetration. Ventilation, vacuum cleaning, and wet cleaning or dry mopping significantly reduced the levels of most contaminants in SHD. As residents are persistently exposed to a wide array of pollutants, comprehensive and adequate measures are required to prevent potential exposures.
URI
https://onlinelibrary.wiley.com/doi/10.1111/ina.13071https://repository.hanyang.ac.kr/handle/20.500.11754/182244
ISSN
0905-6947;1600-0668
DOI
10.1111/ina.13071
Appears in Collections:
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY[E](과학기술융합대학) > MARINE SCIENCE AND CONVERGENCE ENGINEERING(해양융합공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE