112 0

Effect of pump pulsation on particle contamination on wafer surface in wet cleaning system

Title
Effect of pump pulsation on particle contamination on wafer surface in wet cleaning system
Author
박진구
Issue Date
2011-00
Publisher
Electrochemical Society, Inc.
Citation
ECS Transactions, v. 41, NO. 5, Page. 221-227
Abstract
The effects of pumping method on wafer cleaning were investigated. Two types of pump such as diaphragms and centrifugal were used for circulation and supply of DI water for wafer cleaning in both wet bath and single wafer tool. The cleaning studies show that the pumping methods have a great influence on cleaning performance. The experimental investigations reveal that the number of added particles on the wafer during wafer cleaning is much lesser in MLC pump (non-pulsation flow) than the both diaphragm pumps (pulsation flow). ©The Electrochemical Society.
URI
https://iopscience.iop.org/article/10.1149/1.3630847https://repository.hanyang.ac.kr/handle/20.500.11754/181235
ISSN
1938-5862;1938-6737
DOI
10.1149/1.3630847
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MATERIALS SCIENCE AND CHEMICAL ENGINEERING(재료화학공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE