184 150

공동주택 거주자들의 창문개방행위에 따른 연간 자연환기량 분포와 환기부하에 관한 연구

Title
공동주택 거주자들의 창문개방행위에 따른 연간 자연환기량 분포와 환기부하에 관한 연구
Other Titles
Annual Natural Ventilation Rates and Heat and Cooling Load in Relation to Occupant’s Window Opening Behavior in Residential Building
Author
박준석
Keywords
Indoor Air Quality; Occupant behavior; Window opening; Ventilation rates; Ventilation load; 실내공기질; 거주자행동; 창문개방행위; 자연환기량; 환기부하
Issue Date
2022-06
Publisher
한국건축친환경설비학회
Citation
한국건축친환경설비학회 논문집, v. 16, NO. 3, Page. 193-205
Abstract
Recently, due to sick house syndrome, the importance of indoor air quality is emerging. The method of managing the indoor air quality includes mechanical ventilation and natural ventilation. However, the majority of occupants prefer using natural ventilation rather than mechanical ventilation and even don’t know the existence of mandatory mechanical ventilation in residential building. Therefore, recent studies have focused on natural ventilation, which can easily manage the indoor air quality, and propose a ventilation guideline by developing a ventilation module due to the opening of the window. However, hot and cold outdoor air through the window opening affects the indoor temperature, which in turn has a big impact on energy consumption. Previous studies researched the window opening behavior (opening frequency and hours) with outdoor factors and found that the outdoor temperature had the greatest effect on window opening behavior. However, with this only window opening behavior, we couldn’t predict the precise energy consumption and couldn’t purpose the natural ventilation guideline because we don’t know the accurate volume of the outdoor air comes into the building. Therefore, in this study, field measurement is conducted for 4 complexes and 30 samples. we analyze the window opening behavior as same as previous study and the ventilation rates through carbon dioxide decay method. As a result, the measurement period could represent the outdoor temperature of korea. However, despite that outdoor temperature was similar, the distribution of indoor temperature was different by all the samples, especially in heating period. The window opening behavior and ventilation rates have correlation with outdoor temperature. The ventilation load was low in heating period, because of the lack of ventilation behavior. In contrast, the ventilation load in cooling period was greater than that in heating period.
URI
https://www.jkiaebs.org/articles/article/AQ4m/https://repository.hanyang.ac.kr/handle/20.500.11754/176946
ISSN
1976-6483;2586-0666
DOI
10.22696/jkiaebs.20220017
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
86209_박준석.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE