115 0

Full-scale pumping tests of low-viscosity ultra-high-strength concrete

Title
Full-scale pumping tests of low-viscosity ultra-high-strength concrete
Author
류두열
Keywords
Full-scale pumping test; Pressure; Pumpability; Ultra-high-strength concrete; Viscosity
Issue Date
2021-11
Publisher
Elsevier Ltd
Citation
Journal of Building Engineering, v. 43, article no. 102616, Page. 1-8
Abstract
Low-viscosity ultra-high-strength concrete (UHSC) was newly developed by applying viscosity reduction methods, and full-scale pumping tests were performed on a pumping circuit with a total length of 525 m for the low-viscosity UHSC including 150 MPa, 180 MPa UHSC and 180 MPa ultra-high-strength fiber-reinforced concrete (UHSFRC). Concrete properties such as temperature, air content, slump flow, viscosity, compressive strength, and modulus of elasticity before and after pumping were compared. As a result, it was confirmed that pumping caused considerable changes in the properties of fresh concrete. In addition, the pumpability of the low-viscosity UHSCs was evaluated by measuring the pressure of the pipe and the discharge. It was found that the smaller the viscosity and the larger the pressure loss (pressure per unit pipe length), the larger the discharge. © 2021 Elsevier Ltd
URI
https://www.sciencedirect.com/science/article/pii/S2352710221004745?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/176926
ISSN
2352-7102;2352-7102
DOI
10.1016/j.jobe.2021.102616
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE