213 0

A Compact Low-Cost Wideband Shielded-Loop Probe With Enhanced Performance for Magnetic Near-Field Measurements

Title
A Compact Low-Cost Wideband Shielded-Loop Probe With Enhanced Performance for Magnetic Near-Field Measurements
Author
최재훈
Keywords
Electromagnetic interference (EMI); nearfield measurement; planar shielded-loop probe; performance improvement; wideband magnetic-field probe
Issue Date
2020-10
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Citation
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, v. 62, no. 5, page. 1921-1928
Abstract
In this article, a compact low-cost wideband planar shielded-loop probe with enhanced performance is proposed for magnetic near-field measurements. The probe is designed based on a stripline structure and fabricated on an FR4 printed circuit board with a four-layer stack-up structure. In the proposed design, an inverted G-shaped inductive folded line is arranged on an added layer to increase the sensitivity to the magnetic field response. The sensitivity, in terms of |S-21|, of the proposed magnetic near-field probe is improved relative to the conventional shielded-loop by an average of 5 dB over the frequency band ranging from 100 MHz to 6 GHz. Also, two additional techniques to enhance the electric field suppression capability of the planar shielded-loop probe are presented: repositioning the short via hole and mounting a metal can on the probe.
URI
https://ieeexplore.ieee.org/document/8883298https://repository.hanyang.ac.kr/handle/20.500.11754/171159
ISSN
0018-9375; 1558-187X
DOI
10.1109/TEMC.2019.2946714
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRONIC ENGINEERING(융합전자공학부) > Articles