220 0

Exposure of polychlorinated naphthalenes (PCNs) to Pakistani populations via non-dietary sources from neglected e-waste hubs: A problem of high health concern

Title
Exposure of polychlorinated naphthalenes (PCNs) to Pakistani populations via non-dietary sources from neglected e-waste hubs: A problem of high health concern
Author
문효방
Keywords
Human serum; Combustion activities; Halowax; Health risk; Distribution levels
Issue Date
2020-04
Publisher
ELSEVIER SCI LTD
Citation
ENVIRONMENTAL POLLUTION, v. 259, Article no. 113838, 11p
Abstract
To date limited information's are available concerning unintentional productions, screening, profiling, and health risks of polychlorinated naphthalenes (PCNs) in ambient environment and occupational environment. Literature reveals that dust is a neglected environmental matrix never measured for PCNs. To our knowledge, this is the first study to investigate the concentrations and health risks of PCNs in indoor dust, air, and blood of major e-waste recycling hubs in Pakistan. Indoor air (n = 125), dust (n = 250), and serum (n = 250) samples were collected from five major e-waste hubs and their vicinity to measure 39 PCN congeners using GC-ECNI-MS. Sigma 39PCN concentrations in indoor air, dust, and serum (worker ˃ resident ˃ children) samples ranged from 7.0 to 9583 pg/m(3), from 0.25 to 697 ng/g, and from 0.15 to 401 pg/g lipid weight, respectively. Predominant PCN congeners in indoor air and dust were triand tetra-CNs, while tetra- and penta-CNs were dominant in human serum samples. The higher PCNs contribution was recorded at the recycling units, while the lower was observed at the shops of the major e-waste hubs. Higher contribution of combustion origin CNs in air, dust and human samples showed combustion sources at the major e-waste hubs, while Halowax and Aroclor based technical mixture showed minor contribution in these samples. Mean toxic equivalent (TEQ) concentrations of PCNs were 2.79E(+00) pg-TEQ/m(3),1.60E(-02) ng-TEQ/g, 8.11E(-01) pg-TEQ/g, 7.14E(-01) pg-TEQ/g, and 6.37E(-01) m pg-TEQ/g for indoor air, dust, and serum samples from workers, residents, and children, respectively. In our study, CNs- 66/67 and -73 in indoor air, dust, and human serum were the great contributors to total TEQ concentrations of PCNs. This first base line data directs government and agencies to implement rules, regulation to avoid negative health outcomes and suggests further awareness in regard of provision of proper knowledge to the target population. (C) 2019 Elsevier Ltd. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0269749119354429https://repository.hanyang.ac.kr/handle/20.500.11754/164542
ISSN
0269-7491
DOI
10.1016/j.envpol.2019.113838
Appears in Collections:
COLLEGE OF SCIENCE AND CONVERGENCE TECHNOLOGY[E](과학기술융합대학) > MARINE SCIENCE AND CONVERGENCE ENGINEERING(해양융합공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE