219 0

Multispectral image fusion based pedestrian detection using a multilayer fused deconvolutional single-shot detector

Title
Multispectral image fusion based pedestrian detection using a multilayer fused deconvolutional single-shot detector
Author
신현철
Issue Date
2020-04
Publisher
OPTICAL SOC AMER
Citation
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, v. 37, Issue. 5, Page. 768-779
Abstract
Recent research has demonstrated that effective fusion of multispectral images (visible and thermal images) enables robust pedestrian detection under various illumination conditions (e.g., daytime and nighttime). However, there are some open problems such as poor performance in small-sized pedestrian detection and high computational cost of multispectral information fusion. This paper proposes a multilayer fused deconvolutional single-shot detector that contains a two-stream convolutional module (TCM) and a multilayer fused deconvolutional module (MFDM). The TCM is used to extract convolutional features from multispectral input images. Then fusion blocks are incorporated into the MFDM to combine high-level features with rich semantic information and low-level features with detailed information to generate features with strong a representational power for small pedestrian instances. In addition, we fuse multispectral information at multiple deconvolutional layers in the MFDM via fusion blocks. This multilayer fusion strategy adaptively makes the most use of visible and thermal information. In addition, using fusion blocks for multilayer fusion can reduce the extra computational cost and redundant parameters. Empirical experiments show that the proposed approach achieves an 81.82% average precision (AP) on a new small-sized multispectral pedestrian dataset. The proposed method achieves the best performance on two well-known public multispectral datasets. On the KAIST multispectral pedestrian benchmark, for example, our method achieves a 97.36% AP and a 20 fps detection speed, which outperforms the state-of-the-art published method by 6.82% in AP and is three times faster in its detection speed. (C) 2020 Optical Society of America
URI
https://www.osapublishing.org/josaa/fulltext.cfm?uri=josaa-37-5-768&id=431075https://repository.hanyang.ac.kr/handle/20.500.11754/164496
ISSN
1520-8532; 1084-7529
DOI
10.1364/JOSAA.386410
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE