열해현상 방지를 위한 버스 엔진룸 구조개선

Title
열해현상 방지를 위한 버스 엔진룸 구조개선
Other Titles
Reengineering of Bus Engine Room Structure for Preventing Theremal Damages
Author
윤준용
Keywords
열해(Thermal damages); 버스 엔진룸(Bus engine room); 균일도(Uniformity); 순환(Circulation)
Issue Date
2000-05
Publisher
한국자동차공학회
Citation
한국자동차공학회논문집, v. 8, no. 3, page. 46-55
Abstract
Four types of different flow inlet models were tested to improve the flow uniformity at the inlet of the radiator and to prevent thermal damages of auxiliary units from the hot air in the bus engine room. Measurements and numerical calculations were performed and their results were in a good agreement with each other. Simultaneously temperature measurements were carried out under the conditions of actual bus driving. As designing the new flow inlet at the partition board which seperates the engine space and radiator space, flow circulation can be achieved and fresh air comes into the engine room from the bottom. It was proved that new inlet makes the one air temperature cooling down in the engine room, the other uniformity improvement.
URI
https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00524813https://repository.hanyang.ac.kr/handle/20.500.11754/161853