201 0

밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가

Title
밸브 후단 피팅에 따른 밸브 용량계수의 영향 평가
Other Titles
Evaluation of the Effect on the Valve Flow Coefficient by Attached Fitting
Author
윤준용
Keywords
Valve flow coefficient (밸브 용량계수); Piping geometry factor (배관 형상계수); Computational fluid dynamics (전산유체역학); Globe style control valve (글로브 타입 제어밸브)
Issue Date
2003-12
Publisher
한국유체기계학회
Citation
유체기계저널, v. 6, no. 4, page. 29-37
Abstract
This study was undertaken to verify the effect of flow coefficient when a globe control valve was attached by different type of fitting. The valve flow coefficient is usually determined by measuring the flow rate and the pressure drop with the connection of straight pipe through the valve. The effect of different fitting that is mounted on the downstream of the valve is studied. Four types of fittings and three distances between the valve and a downstream fitting are compared parametrically to investigate the effect on the flow coefficient of it. Measured flow coefficient and numerically predicted value by using computational fluid dynamics were compared in detail. It is concluded that the flow coefficient is reduced if the fitting is attached after a valve, but the effect of different type of fitting is not crucial.
URI
http://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE00656332https://repository.hanyang.ac.kr/handle/20.500.11754/156727
ISSN
2287-9706
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE