공동주택 적용을 위한 히트펌프 구동 기반 액체식 제습시스템 제안
- Title
- 공동주택 적용을 위한 히트펌프 구동 기반 액체식 제습시스템 제안
- Other Titles
- Development of heat pump-driven liquid desiccant system for an apartment building
- Author
- 정재원
- Keywords
- 공동주택; 히트펌프; 액체식 제습시스템; 에너지 시뮬레이션; Apartment Building; Heat Pump; Liquid Desiccant; Energy Simulation
- Issue Date
- 2019-11
- Publisher
- 한국생태환경건축학회
- Citation
- 한국생태환경건축학회 학술발표대회 논문집, v. 19, no. 2, Page. 142-143
- Abstract
- The purpose of this research is to compare the energy consumption between two types of heat pump driven liquid desiccant
(HPLD) systems, which are different in mechanism of controlling the desiccant solution. Design and operating strategy of the
two HPLD systems for an apartment building were suggested. One HPLD system simultaneously controls the solution
temperature and concentration at a single sump (Case 1), and the other HPLD system separately controls the solution
temperature and concentration at a dual sump using simple additional devices (Case 2). Energy simulation for air conditioning
in summer was conducted, and the results showed that Case 2 saved 77% of operating energy because the solution cooling and
heating loads were decreased.