423 193

Ingestion Dose Evaluation of Korean Based on Dynamic Model in a Severe Accident

Title
Ingestion Dose Evaluation of Korean Based on Dynamic Model in a Severe Accident
Author
제무성
Keywords
Ingestion dose; Level 3 PSA; Dynamic model; Severe accident; COMIDA2
Issue Date
2018-05
Publisher
대한방사선방어학회
Citation
방사선방어학회지, v. 43, no. 2, page. 50-58
Abstract
Background: In terms of the Level 3 probabilistic safety assessment (Level 3 PSA), ingestion of food that had been exposed to radioactive materials is important to assess the intermediate- and long-term radiological dose. Because the ingestion dose is considerably dependent upon the agricultural and dietary characteristics of each country, the reliability of the assessment results may become diminished if the characteristics of a foreign country are considered. Thus, this study intends to evaluate and analyze the ingestion dose of Korean during a severe accident by completely considering the available agricultural and dietary characteristics in Korea.Materials and Methods: This study uses COMIDA2, which is a program based on dynamic food chain model. It sets the parameters that are appropriate to Korean characteristics so that we can evaluate the inherent ingestion dose of Korean. The results were analyzed by considering the accident date and food category with regard to the 137 Cs.Results and Discussion: The dose and contribution of the food category depicted distinctive differences based on the accident date. Particularly, the ingestion dose during the first and second years depicted a considerable difference by the accident date. However, after the third year, the effect of foliar absorption was negligible and exhibited a similar tendency along with the order of root uptake rate based on the food category.Conclusion: In this study, the agricultural and dietary characteristics of Korea were analyzed and evaluated the ingestion dose of Korean during a severe accident using COMIDA2. By considering the inherent characteristics of Korean, it can be determined that the results of this study will significantly contribute to the reliability of the Level 3 PSA.
URI
http://jrpr.org/journal/view.php?doi=10.14407/jrpr.2018.43.2.50https://repository.hanyang.ac.kr/handle/20.500.11754/118711
ISSN
2508-1888; 2466-2461
DOI
10.14407/jrpr.2018.43.2.50
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
Ingestion Dose Evaluation of Korean Based on Dynamic Model in a Severe Accident.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.