267 0

Seismic retrofit design method using friction damping systems for old low- and mid-rise regular reinforced concrete buildings

Title
Seismic retrofit design method using friction damping systems for old low- and mid-rise regular reinforced concrete buildings
Author
한상환
Keywords
Seismic retrofit; Friction damper; Braced frame; Damping system; Seismic performance; Reinforced concrete
Issue Date
2017-09
Publisher
ELSEVIER SCI LTD
Citation
ENGINEERING STRUCTURES, v. 146, page. 105-117
Abstract
In seismically active regions, many old low- to mid-rise reinforced concrete (RC) buildings are in use that have poor reinforcement details and suffer from material deterioration. Because these buildings are vulnerable to earthquakes, they represent a threat to human lives and economy. To impart such a building with satisfactory seismic performance, a friction damping system can be used, which consists of dampers and a braced frame. In this study, a method for the design of friction damping systems is proposed for the seismic retrofit of old low- to mid-rise regular reinforced concrete (RC) buildings. The proposed method is verified using a six-story RC building designed considering only gravity loads. (C) 2017 Elsevier Ltd. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0141029617302225?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/115642
ISSN
0141-0296; 1873-7323
DOI
10.1016/j.engstruct.2017.05.031
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE