- Abstract
- In this study, field test was performed at the OO reclaimed site in
Gyeonggi-Do to identify field applicability of suction drain method
based on determined effect factors from laboratory tests. A target site
which has thickness of 10m was divided in two sections, and two kinds
of drains selected from laboratory test were installed in each section. To
prevent a loss of vacuum pressure, the upper 1m layer of target site was
left as a sealing layer. Step vacuum pressure was applied to prevent
formation of a ‘Hardening Zone’, and finally 80 kPa of vacuum
pressure were applied