386 0

Local heat transfer characteristics of natural circulation flow inside an 8 x 8 partial spent fuel assembly under dry storage

Title
Local heat transfer characteristics of natural circulation flow inside an 8 x 8 partial spent fuel assembly under dry storage
Author
김성중
Keywords
Dry storage system; Natural circulation; PIV; Local flow field; Heat transfer characteristics
Issue Date
2019-01
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v. 128, Page. 431-442
Abstract
The dry storage system has received immense attention for its safe and passive cooling mechanism as a method for managing highly radioactive spent fuels that inevitably result while using nuclear power. In order to ensure the integrity of the spent fuel cladding, it is important to accurately predict heat transfer characteristics inside the system. In the study, we investigated local flow field and heat transfer characteristics of natural circulation flow at a sub-channel scale inside a downscaled dry storage system. Natural circulation flow was generated with an 8 x 8 rod bundle heaters at a power level equivalent to the decay heat of the spent fuels. The temperature and flow field were measured with thermocouples and the non-intrusive particle image velocimetry (PIV) technique by assuming axisymmetry, respectively. The results indicated that the flow at the upstream of the spacer grid rapidly accelerated at a short distance prior to entering the spacer grid due to blockage effect of a spacer grid. At the downstream, the accelerated flow is discharged as a form of jet and slowly recovers its original velocity with respect to a relatively longer decelerating region. Heat transfer characteristics inside the sub-channels were elucidated by analyzing both flow field and temperature measurements. Empirical correlations for local Nusselt number were derived by using a combination of local Grashof and local Reynolds number. The correlations indicate a clear relation between local flow field and heat transfer characteristics. The flow acceleration caused by the blockage effect of the spacer grid intensified the forced convective effect that increased the local heat transfer rate. (C) 2018 Elsevier Ltd. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0017931018313620?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/103392
ISSN
0017-9310; 1879-2189
DOI
10.1016/j.ijheatmasstransfer.2018.09.002
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.