Quantification of Displacement for Tactile Sensation in a Contact-type Low Intensity Focused Ultrasound Haptic Device

Title
Quantification of Displacement for Tactile Sensation in a Contact-type Low Intensity Focused Ultrasound Haptic Device
Author
김인영
Issue Date
2021-01
Publisher
ASSOC COMPUTING MACHINERY
Citation
ACM TRANSACTIONS ON APPLIED PERCEPTION, v. 18, NO 1, article no. 1, Page. 1-8
Abstract
Tactile threshold of low-intensity focused ultrasound (LIFU) haptic devices has been defined as the minimum pressure required for tactile sensation. However, in contact-type LIFU haptic devices using an elastomer as a conductive medium, the tactile threshold is affected by the mechanical properties of the elastomer. Therefore, the tactile threshold needs to be redefined as a parameter that does not change with the mechanical properties of the elastomer. In this study, we used the LIFU haptic device to investigate the displacement of the elastomer surface at the tactile threshold while controlling the pulse duration, pulse repetition frequency, and pressure. We analyzed the displacement magnitude and rate to determine their relationship to the pressure. The displacement magnitude is the spatiotemporal peak of the displacement, and the displacement rate is the initial slope of the displacement at the starting point of LIFU pulse. The tactile threshold measured by the applied pressure showed the U-shaped graph, and the minimum pressure of 475 kPa at 2 ms and 407 kPa at 300 Hz was measured. The tactile threshold measured by the displacement show that the tactile sensation can be evoked at the small displacement magnitude (˂3 mu m) when the high displacement rate is present (˃1.56 mm/s). Furthermore, the large displacement magnitude is required to induce the tactile sensation when the displacement rate is low. This result shows that the tactile threshold of a contact-type LIFU haptic device is affected by both the displacement magnitude and rate of the conductive medium. Our findings can be used as a guideline for developing a contact-type LIFU haptic device regardless of the elastomer used.
URI
https://dl.acm.org/doi/10.1145/3422820https://repository.hanyang.ac.kr/handle/20.500.11754/175244
ISSN
1544-3558; 1544-3965
DOI
10.1145/3422820
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE