88 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김인영-
dc.date.accessioned2022-10-12T04:33:59Z-
dc.date.available2022-10-12T04:33:59Z-
dc.date.issued2021-01-
dc.identifier.citationACM TRANSACTIONS ON APPLIED PERCEPTION, v. 18, NO 1, article no. 1, Page. 1-8en_US
dc.identifier.issn1544-3558; 1544-3965en_US
dc.identifier.urihttps://dl.acm.org/doi/10.1145/3422820en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/175244-
dc.description.abstractTactile threshold of low-intensity focused ultrasound (LIFU) haptic devices has been defined as the minimum pressure required for tactile sensation. However, in contact-type LIFU haptic devices using an elastomer as a conductive medium, the tactile threshold is affected by the mechanical properties of the elastomer. Therefore, the tactile threshold needs to be redefined as a parameter that does not change with the mechanical properties of the elastomer. In this study, we used the LIFU haptic device to investigate the displacement of the elastomer surface at the tactile threshold while controlling the pulse duration, pulse repetition frequency, and pressure. We analyzed the displacement magnitude and rate to determine their relationship to the pressure. The displacement magnitude is the spatiotemporal peak of the displacement, and the displacement rate is the initial slope of the displacement at the starting point of LIFU pulse. The tactile threshold measured by the applied pressure showed the U-shaped graph, and the minimum pressure of 475 kPa at 2 ms and 407 kPa at 300 Hz was measured. The tactile threshold measured by the displacement show that the tactile sensation can be evoked at the small displacement magnitude (˂3 mu m) when the high displacement rate is present (˃1.56 mm/s). Furthermore, the large displacement magnitude is required to induce the tactile sensation when the displacement rate is low. This result shows that the tactile threshold of a contact-type LIFU haptic device is affected by both the displacement magnitude and rate of the conductive medium. Our findings can be used as a guideline for developing a contact-type LIFU haptic device regardless of the elastomer used.en_US
dc.description.sponsorshipThis work was supported by Samsung Research Funding Center of Samsung Electronics under project number SRFC-IT-1502-05 and a grant of the Korean Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number HI19C0753). Device composition and clinical data collection were conducted with the support of SRFC-IT-1502-05. Analysis of the collected data was conducted with the support of HI19C0753. This work was approved by Institutional Review Board of Hanyang University (Approval Number HYI-17-214-2). All details of the work are registered in Clinical Research Information Service (CRIS) of Korea Centers for Disease Control and Prevention (Register Number KCT0004301), a member of World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP).en_US
dc.language.isoenen_US
dc.publisherASSOC COMPUTING MACHINERYen_US
dc.titleQuantification of Displacement for Tactile Sensation in a Contact-type Low Intensity Focused Ultrasound Haptic Deviceen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume18-
dc.identifier.doi10.1145/3422820en_US
dc.relation.page1-8-
dc.relation.journalACM TRANSACTIONS ON APPLIED PERCEPTION-
dc.contributor.googleauthorChoi, Jeongbong-
dc.contributor.googleauthorYook, Soonhyun-
dc.contributor.googleauthorKim, In Young-
dc.contributor.googleauthorJeong, Mok Kun-
dc.contributor.googleauthorJang, Dong Pyo-
dc.relation.code2021000207-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidiykim-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE