Full metadata record

DC FieldValueLanguage
dc.contributor.author윤준용-
dc.date.accessioned2019-01-10T05:27:42Z-
dc.date.available2019-01-10T05:27:42Z-
dc.date.issued2018-07-
dc.identifier.citationENERGIES, v. 11, No. 7, Article no. 1864en_US
dc.identifier.issn1996-1073-
dc.identifier.urihttps://www.mdpi.com/1996-1073/11/7/1864/htm-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/81223-
dc.description.abstractThe present paper describes some aspects of the bubble size and concentration of a microbubble pump with respect to flow and pressure conditions. The microbubble pump used in the present study has an open channel impeller of a regenerative pump, which generates micro-sized bubbles with the rotation of the impeller. The bubble characteristics are analyzed by measuring the bubble size and concentration using the experimental apparatus consisting of open-loop facilities; a regenerative pump, a particle counter, electronic flow meters, pressure sensors, flow control valves, a torque meter, and reservoir tanks. To control the intake, and the air flowrate upstream of the pump, a high precision flow control valve is introduced. The bubble characteristics have been analyzed by controlling the intake air flowrate and the pressure difference of the pump while the rotational frequency of the pump impeller was kept constant. All measurement data was stored on the computer through the NI (National Instrument) interface system. The bubble size and concentration are mainly affected by three operating parameters: the intake air flowrate, the pressure difference, and the water flowrate supplied to the pump. It is noted that the operating conditions that can most effectively generate microbubbles in the range of 20 to 30 micrometers are at the pressure of 5 bar and at the air flowrate ratio of 4.0 percent for the present pump. Throughout the experimental measurements, it was found that the pump efficiency changed by less than 1.2 percent, depending on the intake air supply. The performance characteristics of microbubble generation obtained by experimental measurements are analyzed and discussed in detail.en_US
dc.description.sponsorshipThis work is supported by a grant (13IFIP-B06700801) from Industrial Facilities & Infrastructure Research Program funded by the Ministry of Land, Infrastructure and Transport of Korea government.en_US
dc.language.isoen_USen_US
dc.publisherMDPI AGen_US
dc.subjectmicrobubble pumpen_US
dc.subjectbubble generationen_US
dc.subjectpump efficiencyen_US
dc.subjectbubble sizeen_US
dc.subjectconcentrationen_US
dc.subjectparticle counteren_US
dc.titleBubble Size and Bubble Concentration of a Microbubble Pump with Respect to Operating Conditionsen_US
dc.typeArticleen_US
dc.relation.no7-
dc.relation.volume11-
dc.identifier.doi10.3390/en11071864-
dc.relation.page1-13-
dc.relation.journalENERGIES-
dc.contributor.googleauthorJeon, Seok-Yun-
dc.contributor.googleauthorYoon, Joon-Yong-
dc.contributor.googleauthorJang, Choon-Man-
dc.relation.code2018005894-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidjoyoon-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE