Full metadata record

DC FieldValueLanguage
dc.contributor.author유지형-
dc.date.accessioned2018-11-26T07:29:39Z-
dc.date.available2018-11-26T07:29:39Z-
dc.date.issued2016-09-
dc.identifier.citationAPPLIED SPECTROSCOPY, v. 70, NO. 6, Page. 1063-1071en_US
dc.identifier.issn0003-7028-
dc.identifier.issn1943-3530-
dc.identifier.urihttps://journals.sagepub.com/doi/10.1177/0003702816641563-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/80650-
dc.description.abstractMinute concentration measurements of simple hydrocarbon gases are demonstrated using near-infrared supercontinuum laser absorption spectroscopy. Absorption-based gas sensors, particularly when combined with optical fiber components, can significantly enhance diagnostic capabilities to unprecedented levels. However, these diagnostic techniques are subject to limitations under certain gas sensing applications where interference and harsh conditions dominate. Supercontinuum laser absorption spectroscopy is a novel laser-based diagnostic technique that can exceed the above-mentioned limitations and provide accurate and quantitative concentration measurement of simple hydrocarbon species while maintaining compatibility with telecommunications-grade optical fiber components. Supercontinuum radiation generated using a highly nonlinear photonic crystal fiber is used to probe rovibrational absorption bands of four hydrocarbon species using full-spectral absorption diagnostics. Absorption spectra of methane (CH4), acetylene (C2H2), and ethylene (C2H4) were measured in the near-infrared spectrum at various pressures and concentrations to determine the accuracy and feasibility of the diagnostic strategy. Absorption spectra of propane (C3H8) were subsequently probed between 1650nm and 1700 nm, to demonstrate the applicability of the strategy. Measurements agreed very well with simulated spectra generated using the HITRAN database as well as with previous experimental results. Absorption spectra of CH4, C2H2, and C2H4 were then analyzed to determine their respective measurement accuracy and detection limit. Concentration measurements integrated from experimental results were in very good agreement with independent concentration measurements. Calculated detection limits of CH4, C2H2, and C2H4 at room temperature and atmospheric pressure are 0.1%, 0.09%, and 0.17%, respectively.en_US
dc.description.sponsorshipThis work was supported by the Air Force Office of Scientific Research (grant number FA9550-14-1-0343).en_US
dc.language.isoenen_US
dc.publisherSOC APPLIED SPECTROSCOPYen_US
dc.subjectSupercontinuumen_US
dc.subjectabsorption spectroscopyen_US
dc.subjecthydrocarbonsen_US
dc.subjectlow-temperature combustionen_US
dc.titleMinute Concentration Measurements of Simple Hydrocarbon Species Using Supercontinuum Laser Absorption Spectroscopyen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume70-
dc.identifier.doi10.1177/0003702816641563-
dc.relation.page1063-1071-
dc.relation.journalAPPLIED SPECTROSCOPY-
dc.contributor.googleauthorYoo, Jihyung-
dc.contributor.googleauthorTraina, Nicholas-
dc.contributor.googleauthorHalloran, Michael-
dc.contributor.googleauthorLee, Tonghun-
dc.relation.code2016001705-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF AUTOMOTIVE ENGINEERING-
dc.identifier.pidjihyungyoo-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > AUTOMOTIVE ENGINEERING(미래자동차공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE