dc.description.abstractFlat plate slab is cost-efficient structural system widely used in high rise building, apartment and parking garages. But flat plate-column connections are so weak against punching shear failure that it may cause collapse of overall structure. In this study, spiral shear reinforcement which increases the shear strength and ductility of the plate-column connection and has good workability was proposed. And experimental test was performed to verify the shear capacity of spiral shear reinforcement. As a result, the test results showed that the strength and deformation capacity of the specimens with the spiral shear reinforcement were improved by 1.47 and 1.5 times those of the unreinforced specimen. The current code does not accurately estimate the punching shear strength of slab-column connection with shear reinforcement because shear strength of concrete does not consider the effects of slab thickness. And slab is so slender that punching failure may occur before shear reinforcement reached yield stress. Therefore, modified equation of ACI code for punching shear strength was proposed by finite element analysis, using LUSAS 14.3.en_US
dc.language.isoenen_US
dc.publisherAmerican Scientific Publishersen_US
dc.subjectFinite element analysisen_US
dc.subjectFlat plate slaben_US
dc.subjectPunching shearen_US
dc.subjectSpiral shear reinforcementen_US
dc.titleAn Analytical Study of Spiral Type Shear Reinforcement Considering Bond Stressen_US
dc.typeArticleen_US
dc.relation.volumeVol.13-
dc.identifier.doi10.1166/asl.2012.3792-
dc.relation.page27-32-
dc.relation.journalADVANCED SCIENCE LETTERS-
dc.contributor.googleauthorChung, Joo-Hong-
dc.contributor.googleauthorJung, Hyung-Suk-
dc.contributor.googleauthorChoi, Chang-Sik-
dc.relation.code2012221330-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidccs5530-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE