dc.description.abstractA 3D computational electromagnetic-thermal coupled analysis was performed to analyze the effects of auxiliary cooling fans, called air-gap fans, on winding cooling in a large-capacity, high-speed induction motor. A novel non-uniform iron loss distribution mapping method considering time and rotation period was introduced to provide more accurate thermal modeling. Winding cooling performance in the motor was calculated and evaluated by considering the variation in thermal-fluid characteristics and thermal flow resulting from the air-gap fans. Results showed that flow rate distributed to the air gap was increased as the stagnant flow disappeared near the air gap because of the air-gap fans. The convective heat transfer coefficient on the winding surface was enhanced by the increased velocity of the internal flow. The heat transfer coefficients at the winding surface and air gap were increased up to 31% and 90%, respectively, due to the increased flow rate. Total winding cooling performance was improved, on average, by 55% with front- and rear-side air-gap fans. For single fan performance, a rear-side air-gap fan was more effective than a front-side air-gap fan. (C) 2016 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by the Business for Cooperative R&D between Industry, Academy, and Research Institute, funded by the Korea Small and Medium Business Administration in 2014 (no. 2014A7279010105).en_US
dc.language.isoenen_US
dc.publisherPERGAMON-ELSEVIER SCIENCE LTDen_US
dc.subjectInduction motoren_US
dc.subjectThermalen_US
dc.subjectNumericalen_US
dc.subjectIron lossen_US
dc.subjectWinding temperatureen_US
dc.titleEffect of air-gap fans on cooling of windings in a large-capacity, high-speed induction motoren_US
dc.typeArticleen_US
dc.relation.volume100-
dc.identifier.doi10.1016/j.applthermaleng.2016.02.077-
dc.relation.page658-667-
dc.relation.journalAPPLIED THERMAL ENGINEERING-
dc.contributor.googleauthorKim, Chiwon-
dc.contributor.googleauthorLee, Kwan-Soo-
dc.contributor.googleauthorYook, Se-Jin-
dc.relation.code2016003906-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.pidysjnuri-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE