Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김용균 | - |
dc.date.accessioned | 2018-04-26T03:49:21Z | - |
dc.date.available | 2018-04-26T03:49:21Z | - |
dc.date.issued | 2013-07 | - |
dc.identifier.citation | 33RD INTERNATIONAL COSMIC RAY CONFERENCE, RIO DE JANEIRO 2013 | en_US |
dc.identifier.uri | http://inspirehep.net/record/1412873/files/icrc2013-0082.pdf | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/70741 | - |
dc.description.abstract | The Basic Atomic Energy Research Institute (BAERI) of Hanyang University in Korea constructed a cosmic ray detection system, which is being operated currently. In this study, neutron ambient dose equivalent rate variation from cosmic ray were analyzed under various environmental conditions using the Excel-based Program for calculating Atmospheric Cosmic-ray Spectrum (EXPACS) applying PHITS (Particle and Heavy Ion Transport code System) based Analytical Radiation Model in the Atmosphere (PARMA). Obtained results were compared with previous other studies and confirmed reliable. Measurement from the detection system was used for evaluation of neutron ambient dose equivalent rate at various environmental conditions in Daejeon. Finally, a conversion coefficient defined as the ratio of counts from the neutron monitor to the neutron ambient dose equivalent was obtained considering atmospheric depth, which have a impact on the conversion coefficient derived. The derived formula was polynomial form with r-square adjusted value of 0.9998. This confirms satisfactory accuracy and reliability of the formula and thereby the legitimate methodology introduced for neutron ambient dose equivalent evaluation using neutron monitor in Daejeon. | en_US |
dc.language.iso | en | en_US |
dc.publisher | THE ASTROPARTICLE PHYSICS CONFERENCE | en_US |
dc.subject | Cosmic ray | en_US |
dc.subject | Neutron monitor | en_US |
dc.subject | NM64 | en_US |
dc.subject | Dose conversion coefficient | en_US |
dc.title | Derivation of Neutron Ambient Dose Using Neutron Monitor in Daejeon | en_US |
dc.type | Article | en_US |
dc.relation.page | 1-4 | - |
dc.contributor.googleauthor | Kim, Yun ho | - |
dc.contributor.googleauthor | Kang, Jeong soo | - |
dc.contributor.googleauthor | Son, Jae bum | - |
dc.contributor.googleauthor | Jang, Doh-yun | - |
dc.contributor.googleauthor | Kim, Sung joong | - |
dc.contributor.googleauthor | Kim, Yong-kyun | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DEPARTMENT OF NUCLEAR ENGINEERING | - |
dc.identifier.pid | ykkim4 | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.