341 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용균-
dc.date.accessioned2018-04-20T01:48:44Z-
dc.date.available2018-04-20T01:48:44Z-
dc.date.issued2011-03-
dc.identifier.citation방사선방어학회지(Journal of Radiation Protection),Vol.36, No.1 [2011], pp.35-43(9)en_US
dc.identifier.issn0253-4231-
dc.identifier.urihttp://www.koreascience.or.kr/article/ArticleFullRecord.jsp?cn=BSBOB5_2011_v36n1_35-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/70277-
dc.description.abstractThe PHENIX Experiment is the largest of the four experiments that have taken data at the Relativistic Heavy Ion Collider. PHENIX, the Pioneering High Energy Nuclear Interaction eXperiment, is designed specifically to measure direct probes of the collisions such as electrons, muons, and photons. The primary goal of PHENIX is to discover and study a new state of matter called the Quark-Gluon Plasma. Among many particles, muons coming from W-boson decay gives us key information to analyze the spin of proton. Resistive plate chambers are proposed as a suitable solution as a muon trigger because of their fast response and good time resolution, flexibility in signal readout, robustness and the relatively low cost of production. The RPC detectors for upgrade were assembled and their performances were evaluated. The procedure to make the detectors better was optimized and described in detail in this thesis. The code based on ROOT was written and by using this the performance of the detectors made was evaluated, and all of the modules for north muon arm met the criteria and installation at PHENIX completed in November 2009. As RPC detectors that we made showed fast response, capacity of covering wide area with a resonable price and good spatial resolution , this will give the opportunity for applications, such as diagnosis and customs inspection system.en_US
dc.language.isoenen_US
dc.publisher대한방사선 방어학회en_US
dc.subjectResistive Plate Chamberen_US
dc.subjectPHENIXen_US
dc.subjectMuon Detectoren_US
dc.subjectCosmic Rayen_US
dc.subjectFast Responseen_US
dc.subjectRPC Detectoren_US
dc.titleDevelopment and Evaluation of the Muon Trigger Detector using a Resistive Plate Chamberen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume36-
dc.relation.page35-43-
dc.relation.journal방사선방어학회지-
dc.contributor.googleauthorPark, Byeong-Hyeon-
dc.contributor.googleauthorKim, Yong-Kyun-
dc.contributor.googleauthorKang, Jeong-Soo-
dc.contributor.googleauthorKim, Young-Jin-
dc.contributor.googleauthorChoi, Ihn-Jea-
dc.contributor.googleauthorKim, Chong-
dc.contributor.googleauthorHong, Byung-Sik-
dc.relation.code2012232530-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidykkim4-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE