259 0

Full metadata record

DC FieldValueLanguage
dc.contributor.authorJan Edward Szulejko-
dc.date.accessioned2018-04-02T01:59:36Z-
dc.date.available2018-04-02T01:59:36Z-
dc.date.issued2014-06-
dc.identifier.citationANALYTICA CHIMICA ACTA, 829, p.32-41en_US
dc.identifier.issn0003-2670-
dc.identifier.issn1873-4324-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0003267014005066-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/54713-
dc.description.abstractFor the quantitative analysis of 'compounds lacking authentic standards or surrogates' (CLASS) in environmental media, we previously introduced an effective carbon number (ECN) approach to develop an empirical equation for the prediction of their response factor (RF). In this research, a series of laboratory experiments were carried out to benchmark the reliability of an ECN approach for sorbent tube/thermal desorption/gas chromatography (GC)/mass spectrometry (MS) applications. First, the ECN values were determined using external calibration data from 25 reference volatile organic compounds (VOCs) using two MS dectectors (quadrupole (Q) and time-of-flight (TOF)). Then, a certified standard mixture of 54 VOCs was analyzed by each system as a simulated unknown sample. The analytical bias, assessed in terms of percentage difference (PD) between the certified and ECN-predicted mass values, averaged 19.2 +/- 16.1% (TOF-MS) and 28.2 +/- 27.6% (Q-MS). The bias using a more simplified carbon number (CN)-based prediction increased considerably, yielding 53.4 +/- 53.3% (TOF-MS) and 61.7 +/- 81.3% (Q-MS). However, the bias obtained using the ECN-based prediction decreased significantly to yield average PD values of 9.84 +/- 7.28% (TOF-MS) and 16.8 +/- 8.35% (Q-MS), if the comparison was limited to 26 (out of 54) VOCs with CN >= 4 (i.e., 25 aromatics and hexachlorobutadiene). (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipThis work was supported by a grant from the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (MEST) (No. 2009-0093848).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BV, PO BOX 211, 1000 AE AMSTERDAM, NETHERLANDSen_US
dc.subjectVolatile organic compounden_US
dc.subjectCarbon numberen_US
dc.subjectEffective carbon numberen_US
dc.subjectSorbent tubeen_US
dc.subjectThermal desorptionen_US
dc.subjectGas chromatography/mass spectrometry applicationsen_US
dc.titleExperimental validation of an effective carbon number-based approach for the gas chromatography-mass spectrometry quantification of 'compounds lacking authentic standards or surrogates'en_US
dc.typeArticleen_US
dc.relation.volume830-
dc.identifier.doi10.1016/j.aca.2014.04.052-
dc.relation.page32-41-
dc.relation.journalANALYTICA CHIMICA ACTA-
dc.contributor.googleauthorKim, Yong-Hyun-
dc.contributor.googleauthorKim, Ki-Hyun-
dc.contributor.googleauthorBae, Min-Suk-
dc.contributor.googleauthorBrown, Richard J. C-
dc.contributor.googleauthorSzulejko, Jan E-
dc.relation.code2014024865-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidshuleiko-
dc.identifier.orcidhttp://orcid.org/0000-0001-7760-8098-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE