Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김진오 | - |
dc.date.accessioned | 2018-03-28T04:25:52Z | - |
dc.date.available | 2018-03-28T04:25:52Z | - |
dc.date.issued | 2013-10 | - |
dc.identifier.citation | 조명전기설비학회논문지, 2013, 27(11), P.89-95 | en_US |
dc.identifier.issn | 1229-4691 | - |
dc.identifier.issn | 2287-5034 | - |
dc.identifier.uri | http://www.dbpia.co.kr/Journal/ArticleDetail/NODE02306377 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11754/53203 | - |
dc.description.abstract | In resent years, Offshore Wind Farm (OWF) is being actively developed. Typically, OWF has a better wind resource than onshore one, but also have a very high investment cost and maintenance cost. Furthermore, due to a difficulty of geographical access, OWF can be affected by the failure for a longer time. As the result, OWF has a higher loss cost. Therefore, a reliability evaluation should be performed more carefully at OWF planning stage. In this paper, a methodology for the reliability evaluation on inner grid is suggested. Inner grid connects wind turbines via submarine cables and transfers power to offshore substation. According to location of the faulted cable under layouts of inner grid, the transfer ability of inner grid is influenced. In order to indicate the transfer ability of inner grid, several indices are introduced such as PNDR, EEND and EENDC. To demonstrate the methodology described in this paper, diversity case studies were performed. | en_US |
dc.description.sponsorship | 본 연구는 2011년도 지식경제부의 재원으로 한국에너지기술평가원(KETEP)의 지원을 받아 수행한 연구 과제입니다. (No. 2011T100200064) | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 한국조명전기설비학회 | en_US |
dc.subject | Offshore Wind Farm | en_US |
dc.subject | Reliability Evaluation | en_US |
dc.subject | Inner Grid | en_US |
dc.subject | Power Not Delivered Ratio(PNDR) | en_US |
dc.subject | Expected Energy Not Delivered(EEND) | en_US |
dc.subject | Expected Energy Not Delivered Cost(EENDC) | en_US |
dc.title | Reliability Evaluation on Offshore Wind Farm | en_US |
dc.title.alternative | 해상풍력단지의 내부 계통망 구성을 위한 신뢰도 평가에 관한 연구 | en_US |
dc.type | Article | en_US |
dc.identifier.doi | 10.5207/JIEIE.2013.27.11.089 | - |
dc.relation.page | 1-5 | - |
dc.contributor.googleauthor | 배인수 | - |
dc.contributor.googleauthor | 신제석 | - |
dc.contributor.googleauthor | 김진오 | - |
dc.contributor.googleauthor | Bae, In-Su | - |
dc.contributor.googleauthor | Shin, Je-Seok | - |
dc.contributor.googleauthor | Kim, Jin-O | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING | - |
dc.identifier.pid | jokim | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.