316 0

영가철 충진 컬럼을 이용한 연속적인 물리화학적 수중 인 제거

Title
영가철 충진 컬럼을 이용한 연속적인 물리화학적 수중 인 제거
Other Titles
Continuous removal of phosphorus in water by physicochemical method using zero valent iron packed column
Author
박주양
Keywords
전기응집; 전해조; 인산염; 침전; 하수처리장; 영가철
Issue Date
2013-08
Publisher
대한상하수도학회
Citation
ournal of Korean Society of Water and Wastewater, 2013, 27(4), pp.439 - 444
Abstract
Excessive phosphorus in aquatic systems causes algal bloom resulting in eutrophication, DO depletion, decline in recreational value of water and foul tastes. To treat wastewater containing phosphorus including effluent of wastewater treatment plant, the continuous experiments were performed by using electrochemical way. The spherical ZVI and silica sand which act as physical filter are packed at appropriate volume ratio of 1:2. Electric potential is applied externally which can be changed as per the operational requirement. The results indicate that optimum hydraulic retention time of 36 minutes (10 mL/min at 1 L reactor) was required to meet the effluent standards. Lower concentrations of phosphorus
URI
http://koreascience.or.kr/article/ArticleFullRecord.jsp?cn=SHSDB3_2013_v27n4_439http://www.ndsl.kr/ndsl/search/detail/article/articleSearchResultDetail.do?cn=JAKO201307954671381
ISSN
1225-7672
DOI
10.11001/jksww.2013.27.4.439