365 0

Effects of amplitude and frequency on the wear mode change of Inconel 690 SG tube mated with SUS 409

Title
Effects of amplitude and frequency on the wear mode change of Inconel 690 SG tube mated with SUS 409
Author
김선진
Keywords
retting; iliding wear; nconel 690.5team generator; Wear coefficient
Issue Date
2014-05
Publisher
ELSEVIER SCIENCE SA, PO BOX 564, 1001 LAUSANNE, SWITZERLAND
Citation
WEAR, 권: 313, 호: 1-2, 페이지: 83-88
Abstract
Steam generator (SG) tubes in certain types of nuclear power plants experience flow-induced vibrations that can result in fretting wear. The wear mode under these conditions can change with wear variables. Using a custom-designed fretting test apparatus, the effects of amplitude and frequency on wear mode changes for Inconel 690 SG tubes mated with SUS 409 were investigated. Changes in the wear mode were found by using periodic measurements of weight loss to calculate wear coefficients. The wear mode was observed to change from stick to gross slip and sliding as amplitude increased from 25 mu m to 300 pm. However, the wear mode did not change with increasing frequency or testing duration within the range of applied conditions. (C) 2014 Elsevier B.V. All rights reserved.
URI
https://www.sciencedirect.com/science/article/abs/pii/S0043164814000635http://hdl.handle.net/20.500.11754/49670
ISSN
0043-1648
DOI
10.1016/j.wear.2014.02.019
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MATERIALS SCIENCE AND ENGINEERING(신소재공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE