dc.description.abstractRecently, multiple glazing units, frames, complex fenestration systems, and windows with shading devices have been developed to save cooling energy in buildings. However, very little work has been conducted on developing a direct experimental test method of the solar heat gain coefficient(SHGC) for new fenestration techniques. This study aims to develop and evaluate a test apparatus to measure the SHGC, according to the KS L 9107 test method. The performance of the solar simulator was class A, B, and A, for spectral match, non-uniformity, and instability irradiance, respectively. The differences between the measured and calculated SHGC values were found to range between 0.001 and 0.011, and for all test specimens they agreed within 4%. These results establish the validity of the test apparatus. This system is thus expected to be useful in assessing the energy performance for various types of fenestration.en_US
dc.language.isootheren_US
dc.publisher대한설비공학회 / The Society Of Air-Conditioning And Refrigerating Engineers Of Koreaen_US
dc.subject태양열 취득률en_US
dc.subject열공학과 원동기en_US
dc.subject냉방에너지en_US
dc.subjectKS L 9107en_US
dc.subjectSHGCen_US
dc.subjectFenestrationen_US
dc.subjectCooling energyen_US
dc.subjectTest methoden_US
dc.titleKS L 9107에 의한 태양열 취득률(SHGC) 측정장치 개발 및 평가en_US
dc.title.alternativeDevelopment and Evaluation of an Apparatus to Measure the Solar Heat Gain Coefficient of a Fenestration System According to KS L 9107en_US
dc.typeArticleen_US
dc.relation.no11-
dc.relation.volume26-
dc.relation.page512-521-
dc.relation.journal설비공학 논문집-
dc.contributor.googleauthor김태중-
dc.contributor.googleauthor최현중-
dc.contributor.googleauthor강재식-
dc.contributor.googleauthor박준석-
dc.contributor.googleauthorKim, Tae-Jung-
dc.contributor.googleauthorChoi, Hyun-Jung-
dc.contributor.googleauthorKang, Jae-Sick-
dc.contributor.googleauthorPark, Jun-Seok-
dc.relation.code2014001095-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjunpark-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE