dc.identifier.citationAtmospheric pollution research,v.5 no.3, 2014년, pp.563 - 571en_US
dc.identifier.issn1309-1042-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S1309104215303147?via%3Dihub-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/48893-
dc.description.abstractIn this study, the matrix effect on the quantitation of volatile organic compounds (VOCs) at sub-ppm levels has been investigated in relation to the selected standard phase by direct injection gas chromatographic (GC) analysis. To this end, a series of calibration experiments were conducted using both liquid and gas phase standards containing identically a total of 13 target VOCs. Calibration datasets between liquid and gas standards were obtained at the four selected injection volumes, i.e., covering a 1 to 5 and 50 to 500 mu L range, respectively. The results indicate that injection volume is a sensitive parameter, as sensitivity tends to decrease with increasing injection volume, especially with liquid standards. Loss of analytes in liquid standard occurred noticeably from ones eluting earlier than solvent used for standard (i.e., methanol). If the extent of such loss is expressed by the percent differences in the response factor (RF) values between two standard types, the results were low or insignificant for valeraldehyde (0.48%), benzene (7.6%), toluene (3.3%), and styrene (4.8%) but generally high for the others (i.e., between 10-80%). The relative sensitivities of VOCs in gaseous standards, if computed by normalization against benzene, generally complied well with those derivable from the literature on flame ionization detectors. In contrast, in case of liquid standards, the use of a small injection volume (<= 1 mu L) is recommended to maintain the optimal GC performance in light of the matrix effect.en_US
dc.description.sponsorshipThis research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (Grant No 2013?004 624).en_US
dc.language.isoenen_US
dc.publisherTURKISH NATL COMMITTEE AIR POLLUTION RES &CONTROL-TUNCAP, DOKUZ EYLUL UNIV, DEPT ENVIRONMENTAL ENGINEERING, TINAZTEPE CAMPUS, BUCA, IZMIR 35160, TURKEYen_US
dc.subjectVolatile organic compound (VOC)en_US
dc.subjectinjection volumeen_US
dc.subjectsensitivityen_US
dc.subjectfixed standard volume (FSV)en_US
dc.subjectcalibration/response factoren_US
dc.titleThe selection of the standard phase (gas vs. liquid) and the related matrix effect on the direct injection gas chromatographic analysis of VOCs at sub-ppm levelsen_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume5-
dc.identifier.doi10.5094/APR.2014.065-
dc.relation.page563-571-
dc.relation.journalATMOSPHERIC POLLUTION RESEARCH-
dc.contributor.googleauthorIqbal, Mohammad Asif-
dc.contributor.googleauthorKim, Ki?Hyun-
dc.contributor.googleauthorSzulejko, Jan E.-
dc.contributor.googleauthorRahman, Md. Mahmudur-
dc.relation.code2014025736-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidkkim61-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles