실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구

Title
실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구
Author
박준석
Keywords
태양열 취득률; 열관류율; 베네시안 블라인드; 롤스크린; 냉방에너지; Solar Heat Gain Coefficient , SHGC; U-value; Venetian blind; Roll screen; Cooling energy
Issue Date
2014-10
Publisher
한국태양에너지학회
Citation
한국태양에너지학회 논문집, 2014, 34(5), P.89-99
Abstract
The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient(SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to -45˚, 0˚, and ?45˚. For the roll screen, measurements were taken with the roll screen in the closed position. In results, the venetian blind reduced SHGC by 21.2~28.4% at 45˚, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind ?45˚, 0˚and 45˚, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.
URI
http://www.ndsl.kr/ndsl/search/detail/article/articleSearchResultDetail.do?cn=JAKO201433552234094http://koreascience.or.kr/article/ArticleFullRecord.jsp?cn=TOONB4_2014_v34n5_89
ISSN
1598-6411
DOI
10.7836/kses.2014.34.5.089
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE