264 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author박관규-
dc.date.accessioned2018-03-14T00:21:17Z-
dc.date.available2018-03-14T00:21:17Z-
dc.date.issued2013-06-
dc.identifier.citationIEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, JUN 2013, 60(6), p1245-p1255en_US
dc.identifier.issn0885-3010-
dc.identifier.urihttp://ieeexplore.ieee.org/abstract/document/6521074/-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/46386-
dc.description.abstractThis paper presents a comprehensive comparison between a collapse-mode and a conventional-mode capacitive micromachined ultrasonic transducer (CMUT); both devices have a 1-mu m-thick silicon plate and operate at 10 MHz when biased at 100 V. The radii of the circular plates and the gap heights are modified to meet the design specifications required for a fair comparison. Finite element analysis (FEA) shows that the collapse-mode CMUT has higher output pressure sensitivity (46.5 kPa/V) than the conventional CMUT (13.1 kPa/V), and achieves a 3-dB fractional bandwidth (FBW) of 124% compared with 128% for the conventional mode. These results were validated by experiments performed on devices fabricated in a 1-D phased array configuration using the local oxidation of silicon (LOCOS)/wafer-bonding process. The measured output pressure sensitivity and the FBW of the collapse-mode and the conventional CMUTs at 100 V were 26.4 kPa/V and 103% and 12.7 kPa/V and 111%, respectively. The maximum output pressure of the collapse-mode CMUT was 1.19 MPa at 10 MHz, which was much higher than the conventional CMUT (0.44 MPa). However, the second harmonic distortion (SHD) level of the collapse-mode CMUT is higher than the conventional CMUT at the same excitation condition. Even with higher electric field in the cavity, the collapse-mode CMUT was as stable as the conventional CMUT in a long-term test. A 30-h test with a total of 3.2 x 10(9) cycles of 30 V ac excitation resulted in no significant degradation in the performance of the collapse-mode devices.en_US
dc.language.isoenen_US
dc.publisherIEEE INSTITUTE OF ELECTRICAL AND ELECTRONICSen_US
dc.subjectOPERATIONen_US
dc.subjectCIRCUITen_US
dc.titleA Comparison Between Conventional and Collapse-Mode Capacitive Micromachined Ultrasonic Transducers in 10-MHz 1-D Arraysen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume60-
dc.identifier.doi10.1109/TUFFC.2013.2688-
dc.relation.page1245-1255-
dc.relation.journalIEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL-
dc.contributor.googleauthorPark, Kwan Kyu-
dc.contributor.googleauthorOralkan, Omer-
dc.contributor.googleauthorKhuri-Yakub, Butrus T.-
dc.relation.code2013010209-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.pidkwankyu-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE