Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이주 | - |
dc.date.accessioned | 2018-03-13T04:47:05Z | - |
dc.date.available | 2018-03-13T04:47:05Z | - |
dc.date.issued | 2013-12 | - |
dc.identifier.citation | 照明·電氣設備學會論文誌 / Journal of the Korean institute of illuminating and electrical installation engineers, Vol.27, No.12 [2013], p125-132 | en_US |
dc.identifier.issn | 1229-4691 | - |
dc.identifier.uri | http://www.dbpia.co.kr/Journal/ArticleDetail/NODE02319452 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11754/45886 | - |
dc.description.abstract | This paper has done a three-dimensional FEM analysis of the PM claw pole stepping motor. As magnetization happens in the z-axis, which does not have a constant value, three-dimensional FEM analysis is necessary for characteristic analysis of PM claw pole stepping motors. Because it is a type of permanent magnet motor, the PM claw pole stepping motor naturally has a detent torque. This torque is known to show negative effects on motor performance. To improve motor performance, reducing the detent torque is very important during the motor design. This paper applied DOE for optimization of stator pole design of the motor. Also, we compared motor performance by applying a different type of rotor shape, dividing the permanent magnet. To verify the simulation results, an experiment was done. | en_US |
dc.description.sponsorship | This research was financially supported by the Ministry of Trade, Industry & Energy (MOTIE), the Korea Institute for Advancement of Technology (KIAT), and the Honam Institute for Regional Program Evaluation through the Leading Industry Development for Economic Region. | en_US |
dc.language.iso | en | en_US |
dc.publisher | 한국조명·전기설비학회 | en_US |
dc.subject | PM | en_US |
dc.subject | Permanent Magnet | en_US |
dc.subject | Detent Torque | en_US |
dc.subject | Claw Pole | en_US |
dc.subject | DOE | en_US |
dc.subject | Motor | en_US |
dc.title | A Study on the Detent Torque Reduction of Claw Pole Permanent Magnet Type Motor | en_US |
dc.type | Article | en_US |
dc.relation.no | 12 | - |
dc.relation.volume | 27 | - |
dc.identifier.doi | 10.5207/JIEIE.2013.27.12.125 | - |
dc.relation.page | 125-132 | - |
dc.relation.journal | 조명.전기설비학회논문지 | - |
dc.contributor.googleauthor | Jung, Dae-Sung | - |
dc.contributor.googleauthor | Lee, Ju | - |
dc.contributor.googleauthor | Lee, Sang-Taek | - |
dc.relation.code | 2012212364 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING | - |
dc.identifier.pid | julee | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.