351 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정윤선-
dc.date.accessioned2018-03-10T01:35:04Z-
dc.date.available2018-03-10T01:35:04Z-
dc.date.issued2013-05-
dc.identifier.citationOncology Research and Treatment, 2013, 36(5), P.241-246en_US
dc.identifier.issn0378-584X-
dc.identifier.issn2296-5270-
dc.identifier.urihttp://www.karger.com/Article/Pdf/350299-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/44547-
dc.description.abstractBackground: The aim of this study was to investigate the effect of a belly board (BB) with the addition of a bladder compression device (BCD) for small bowel (SB) displacement from the radiotherapy field for rectal cancer. Patients and Methods: Computed tomography (CT) scans of 38 rectal cancer patients positioned on a BB were analyzed and compared with CT scans from the same patients after the addition of a BCD. The BCD moves the inferior border of the BB from the pubic symphysis to the lumbosacral junction. The treated and irradiated volumes of the SB and bladder were compared. The irradiated volume ratio of SB to abdominopelvic cavity (APC) and that of bladder to APC were analyzed. Results: With the BCD, the treated and irradiated volumes of SB decreased significantly (49.1 +/- 48.0 vs. 60.9 +/- 50.9 cc, p = 0.006 and 207.5 +/- 140.8 vs. 482.8 +/- 214.2 cc, p < 0.001, respectively). The irradiated volume ratio of bladder to APC with the BCD increased considerably compared to that without the BCD (25.2 +/- 11.5 vs. 18.7 +/- 10.5%, p < 0.001), and the ratio of irradiated volume of SB to APC decreased significantly with the BCD (18.8 +/- 12.4 vs. 31.8 +/- 12.1%, p < 0.001). Conclusion: This study showed that the addition of a BCD to the BB could effectively provide further displacement of SB from the rectal cancer radiotherapy field.en_US
dc.description.sponsorshipThis study was supported by a grant from the Korea Healthcare Technology R and D Project, Ministry for Health, Welfare and Family Affairs, and the Republic of Korea (A084120).en_US
dc.language.isoenen_US
dc.publisherKARGERen_US
dc.subjectRectal canceren_US
dc.subjectBelly boarden_US
dc.subjectBladder compression deviceen_US
dc.subjectSmall bowelen_US
dc.subjectBladderen_US
dc.titleEffect of Belly Board with Bladder Compression Device on Small Bowel Displacement from the Radiotherapy Field for Rectal Canceren_US
dc.typeArticleen_US
dc.identifier.doi10.1159/000350299-
dc.relation.journalONKOLOGIE-
dc.contributor.googleauthorChung, Yoonsun-
dc.contributor.googleauthorYoon, Hong I.-
dc.contributor.googleauthorKeum, Ki C.-
dc.contributor.googleauthorKim, Joo H.-
dc.contributor.googleauthorChoi, Won H.-
dc.contributor.googleauthorNam, Ki C.-
dc.contributor.googleauthorKoom, Woong S.-
dc.relation.code2013011544-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidychung-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE