349 103

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용수-
dc.date.accessioned2018-03-06T02:19:32Z-
dc.date.available2018-03-06T02:19:32Z-
dc.date.issued2013-02-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY, FEB 2013, 45(1), 115~124페이지en_US
dc.identifier.issn1738-5733-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S1738573315300140?via%3Dihub-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/42845-
dc.description.abstractAmong the several options to solve PWR spent fuel accumulation problem in Korea, the dry storage method could be the most realistic and applicable solution in the near future. As the basic objectives of dry storage are to prevent a gross rupture of spent fuel during operation and to keep its retrievability until transportation, at the same time the importance of a spent fuel integrity evaluation that can estimate its condition at the final stage of dry storage is very high. According to the national need and technology progress, two representative nations of spent fuel dry storage, the USA and Japan, have established different system temperature criteria, which is the only controllable factor in a dry storage system. However, there are no technical criteria for this evaluation in Korea yet, it is necessary to review the previously well-organized methodologies of advanced countries and to set up our own domestic evaluation direction due to the nation's need for dry storage. To satisfy this necessity, building a domestic spent fuel test database should be the first step. Based on those data, it is highly recommended to compare domestic data range with foreign results, to build our own criteria, and to expand on evaluation work into recently issued integrity problems by using a comprehensive integrity evaluation code.en_US
dc.description.sponsorshipThis work has been carried out under the Nuclear R&D Program supported by the Ministry of Knowledge & Economy (MKE), Korea.en_US
dc.language.isoenen_US
dc.publisherKOREAN NUCLEAR SOCen_US
dc.subjectSpent Fuelen_US
dc.subjectIntegrityen_US
dc.subjectDry Storageen_US
dc.subjectISSUESen_US
dc.titleREVIEW OF SPENT FUEL INTEGRITY EVALUATION FOR DRY STORAGEen_US
dc.typeArticleen_US
dc.relation.no1-
dc.relation.volume45-
dc.identifier.doi10.5516/NET.06.2012.016-
dc.relation.page115-124-
dc.relation.journalNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.contributor.googleauthorKook, Dong-Hak-
dc.contributor.googleauthorChoi, Jong-won-
dc.contributor.googleauthorKim, Ju-Seong-
dc.contributor.googleauthorKim, Yong-Soo-
dc.relation.code2013006598-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidyongskim-


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE