343 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author구자윤-
dc.date.accessioned2018-02-28T00:29:11Z-
dc.date.available2018-02-28T00:29:11Z-
dc.date.issued2016-03-
dc.identifier.citationIET SCIENCE MEASUREMENT & TECHNOLOGY, V. 10, No. 2, Page. 111-119en_US
dc.identifier.issn1751-8822-
dc.identifier.issn1751-8830-
dc.identifier.urihttp://digital-library.theiet.org/content/journals/10.1049/iet-smt.2015.0125-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/40932-
dc.description.abstractEven though a lot of research has been devoted to find partial discharge (PD) sources based on the time difference of pulses, it has been reported that studies have been unable to obtain precise locations in joints due to the errors caused by the attenuation or distortion of PD pulses. In this study, in order to reduce the issues, ‘Precise PD finding’ is developed to obtain the accurate locations of PD sources by considering not only the time difference of pulses, but also pulse polarity. Accordingly, a PD detection algorithm is implemented. An attachable inductive sensor is designed and fabricated and then applied to a real scaled 154 kV XLPE cable with a joint. From the experimental results, the algorithm was verified to successfully find the locations of PD sources. The algorithm was then applied to an on-site, 345 kV XLPE cable. Consequently, PD sources were detected in a normal straight joint box and confirmed through a disassembly investigation.en_US
dc.description.sponsorshipThis work was supported by the Human Resources Program in Energy Technology of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea (20154030200730).en_US
dc.language.isoen_USen_US
dc.publisherINST ENGINEERING TECHNOLOGY-IETen_US
dc.subjectLOCATIONen_US
dc.subjectPULSESen_US
dc.subjectPDen_US
dc.titleDevelopment of a partial discharge detection algorithm and verification test for extra-high-voltage cable systemen_US
dc.typeArticleen_US
dc.identifier.doi10.1049/iet-smt.2015.0125-
dc.relation.page1-9-
dc.relation.journalIET SCIENCE MEASUREMENT & TECHNOLOGY-
dc.contributor.googleauthorChoi, Won-
dc.contributor.googleauthorKim, Jeong-Tae-
dc.contributor.googleauthorSeo, In-Jin-
dc.contributor.googleauthorHwang, Jae-Sang-
dc.contributor.googleauthorKoo, Ja-Yoon-
dc.relation.code2015002827-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDIVISION OF ELECTRICAL ENGINEERING-
dc.identifier.pidkoojy-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE