256 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author양현익-
dc.date.accessioned2018-02-09T06:45:53Z-
dc.date.available2018-02-09T06:45:53Z-
dc.date.issued2015-11-
dc.identifier.citationPHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, v. 74, Page. 39-44en_US
dc.identifier.issn1386-9477-
dc.identifier.issn1873-1759-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S1386947715300801?via%3Dihub-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/36381-
dc.description.abstractA mass sensor using a moo resonator has high detection sensitivity, and mass sensitivity is higher with smaller resonators. Therefore, carbon nanotubes (CNTs) are the ultimate materials for these applications and have been actively studied. In particular, CNT-based nanomechanical devices may experience high temperatures that lead to thermal expansion and residual stress in devices, which affects the device reliability. In this letter, to demonstrate the influence of the temperature change (i.e., thermal effect) on the mass detection sensitivity of CNT-based mass sensor, dynamic analysis is carried out for a CNT resonator with thermal effects in both linear and nonlinear oscillation regimes. Based on the continuum mechanics model, the analytical solution method with an assumed deflection eigenmode is applied to solve the nonlinear differential equation vvhich involves the von Karman nonlinear strain displacement relation and the additional axial force associated with thermal effects. A thermal effect on the fundamental resonance behavior and resonance frequency shift due to adsorbed mas, i.e., mass detection sensitivity, is examined in high-temperature environment. Results indicate a valid improvement of Fundamental resonance frequency by using nonlinear oscillation in a thermal environment. In both linear and nonlinear oscillation regimes, the mass detection sensitivity becomes worse due to the increasing of temperature in a high-temperature environment. The thermal effect on the detection sensitivity is less effective in the nonlinear oscillation regime. It is concluded that a temperature change of a mass sensor with a CNT-based resonator can be utilized to enhance the detection sensitivity depending on the CNT length, linear/nonlinear oscillation behaviors, and the thermal environment. (C) 2015 Elsevier B.V. All rights reserveden_US
dc.description.sponsorshipThis paper was supported by Konkuk University in 2014.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectThermal effecten_US
dc.subjectCarbon nanotube(CNT)en_US
dc.subjectNonlinear oscillationen_US
dc.subjectMass sensoren_US
dc.subjectTemperature changeen_US
dc.subjectMass detection sensitivityen_US
dc.subjectNANOMECHANICAL RESONATORSen_US
dc.subjectVIBRATIONen_US
dc.subjectEXPANSIONen_US
dc.subjectMECHANICSen_US
dc.subjectSWITCHen_US
dc.titleThermal effects on mass detection sensitivity of carbon nanotube resonators in nonlinear oscillation regimeen_US
dc.typeArticleen_US
dc.relation.volume74-
dc.identifier.doi10.1016/j.physe.2015.06.009-
dc.relation.page39-44-
dc.relation.journalPHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES-
dc.contributor.googleauthorKang, Dong-Keun-
dc.contributor.googleauthorYang, Hyun-Ik-
dc.contributor.googleauthorKim, Chang-Wan-
dc.relation.code2015000575-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDEPARTMENT OF MECHANICAL ENGINEERING-
dc.identifier.pidskynet-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE