234 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2018-02-07T08:38:25Z-
dc.date.available2018-02-07T08:38:25Z-
dc.date.issued2011-07-
dc.identifier.citationNuclear technology,Vol.175 No.1 [2011],11-15en_US
dc.identifier.issn0029-5450-
dc.identifier.issn1943-7471-
dc.identifier.urihttp://www.tandfonline.com/doi/abs/10.13182/NT11-A12262-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/36009-
dc.description.abstractIn proton therapy, accurate verification of in vivo dose distribution is necessary to ensure not only the safety of the patient but also the success of the treatment itself It has been shown, both by Monte Carlo simulations and by limited experiments, that the proton beam range in a patient can be accurately determined by measuring the distribution of the prompt gammas generated from proton-induced nuclear interactions. In the present study, a two-dimensional (2-D) prompt gamma detection system incorporating a 51 (longitudinal) X 21 (lateral) detector array was designed and tested by Monte Carlo simulations using the MCNPX code. Additionally, the detection probability of the prompt gammas per primary proton was calculated for different proton energies. Despite the increase of the beam dispersion effect and background gammas with the increase of the proton energy, our simulation results clearly showed that it is possible to measure the 2-D distribution of prompt gammas up to 150 MeV using the 2-D prompt gamma detection system.en_US
dc.language.isoenen_US
dc.publisherAMER NUCLEAR SOC, 555 N KENSINGTON AVE, LA GRANGE PK, IL 60526 USAen_US
dc.subjectproton therapyen_US
dc.subjectprompt gammaen_US
dc.subjectMonte Carlo simulationen_US
dc.subjectEDGEen_US
dc.titleTWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDYen_US
dc.typeArticleen_US
dc.relation.volume175-
dc.identifier.doi10.13182/NT11-A12262-
dc.relation.page11-15-
dc.relation.journalNUCLEAR TECHNOLOGY-
dc.contributor.googleauthorMin, Chul Hee-
dc.contributor.googleauthorLee, Han Rim-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.relation.code2011207177-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE