255 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김진오-
dc.date.accessioned2018-02-03T06:01:41Z-
dc.date.available2018-02-03T06:01:41Z-
dc.date.issued2011-03-
dc.identifier.citation전기학회논문지, v. 60, NO 3, Page. 465-470en_US
dc.identifier.issn1229-2443-
dc.identifier.issn1229-246x-
dc.identifier.urihttp://click.ndsl.kr/servlet/LinkingDetailView?cn=JAKO201110949597262&dbt=JAKO&org_code=O483&site_code=SS1483&service_code=01-
dc.identifier.urihttp://koreascience.or.kr/article/ArticleFullRecord.jsp?cn=DHJGII_2011_v60n3_465-
dc.description.abstractRecently fault currents are increasing in a network. It is caused by increase in electric demand and high penetration of distributed generation with renewable energy sources. Moreover, distribution network has become more and more complex as mesh network to improve the distribution system reliability and increase the flexibility and agility of network operation. Accordingly, the fault current will exceed capacity of circuit breakers soon and all the various rational solutions to solve this problem are taken into account. Under these circumstances, superconducting fault current limiter(SFCL) is a new alternative in the viewpoint of technical and economic aspects. This study presents operation processes for a resistive-type of SFCL, and it proposes reliability model for the SFCL. When a SFCL is installed into a network, the contribution of decreased fault currents to failure for distribution equipments can be quantified. As a result, it is expected that a SFCL makes the reliability of adjacent equipments on existing network improve and these changes are analyzed. We propose a methodology to evaluate the reliability in the distribution network where a SFCL is installed considering a reliability model for resistive-type of SFCL and reliability changes for adjacent equipments which are proposed in this paper.en_US
dc.language.isoko_KRen_US
dc.publisher대한전기학회en_US
dc.subjectSuperconducting fault current limiteren_US
dc.subjectReliability modelen_US
dc.subjectDistribution reliabilityen_US
dc.title저항형 초전도한류기의 신뢰도 모델을 적용한 배전계통 신뢰도 평가에 관한 연구en_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume60-
dc.identifier.doi10.5370/KIEE.2011.60.3.465-
dc.relation.page465-470-
dc.relation.journal전기학회논문지-
dc.contributor.googleauthor김성열-
dc.contributor.googleauthor김욱원-
dc.contributor.googleauthor김진오-
dc.contributor.googleauthorKim, Sung-Yul-
dc.contributor.googleauthorKim, Wook-Won-
dc.contributor.googleauthorKim, Jin-O-
dc.relation.code2012215931-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING-
dc.identifier.pidjokim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE