257 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정회일-
dc.date.accessioned2018-02-03T05:31:45Z-
dc.date.available2018-02-03T05:31:45Z-
dc.date.issued2011-03-
dc.identifier.citationJOURNAL OF RAMAN SPECTROSCOPY, v. 42, NO 3, Page. 445-451en_US
dc.identifier.issn0377-0486-
dc.identifier.urihttp://onlinelibrary.wiley.com/doi/10.1002/jrs.2712/abstract;jsessionid=3B3B830B7C775E703FB3FE9429455D54.f04t04?systemMessage=Please+be+advised+that+we+experienced+an+unexpected+issue+that+occurred+on+Saturday+and+Sunday+January+20th+and+21st+that+caused+the+site+to+be+down+for+an+extended+period+of+time+and+affected+the+ability+of+users+to+access+content+on+Wiley+Online+Library.+This+issue+has+now+been+fully+resolved.++We+apologize+for+any+inconvenience+this+may+have+caused+and+are+working+to+ensure+that+we+can+alert+you+immediately+of+any+unplanned+periods+of+downtime+or+disruption+in+the+future.-
dc.description.abstractWe present a reliable and nondestructive analytical method for the determination of urea concentration in a pharmaceutical cream formulation using Raman spectroscopy. A pharmaceutical cream is a highly viscous emulsion; therefore, its composition and physical mixing could be inhomogeneous on a microscopic scale. The local environment around the urea could vary, which could influence the molecular vibrations of the urea molecule. As expected, when Raman spectra were collected by focusing the laser onto a tiny area (similar to 2-3 mu m), the position of the urea band at 1003 cm(-1) varied as a result of the microscopic inhomogeneity within the sample. Therefore, acquisition of Raman spectra representative of the entire sample rather than a localized portion of it is very important for the analysis of pharmaceutical creams. Based on the preliminary Raman mapping results of a urea cream, a sample area of at least 750 x 750 mu m should be covered for reliable quantitative analysis. In this study, we used a wide-area illumination scheme capable of covering a sample area of 28.3 mm(2) for Raman spectral collection in order to ensure a reliable representative sample. In addition, to simplify the measurements, Raman spectra of urea creams in plastic bottles were directly collected without further sampling, and partial least squares regression was used for quantitative analysis. The urea concentrations were accurately determined despite the spectral collection being performed through plastic bottles. Copyright (C) 2010 John Wiley & Sons, Ltd.en_US
dc.description.sponsorshipThis research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2007000 00006626)en_US
dc.language.isoenen_US
dc.publisherJOHN WILEY & SONS LTDen_US
dc.subjecturea creamen_US
dc.subjectcream formulationen_US
dc.subjectsample representationen_US
dc.subjectemulsionen_US
dc.subjectwide area illuminationen_US
dc.titleReliable and non-destructive Raman analysis to determine the urea concentration in a cream formulationen_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume42-
dc.identifier.doi10.1002/jrs.2712-
dc.relation.page445-451-
dc.relation.journalJOURNAL OF RAMAN SPECTROSCOPY-
dc.contributor.googleauthorOh, C.-
dc.contributor.googleauthorSriphong, L.-
dc.contributor.googleauthorKim, M.-
dc.contributor.googleauthorChung, H.-
dc.contributor.googleauthorAsavapichayont, P.-
dc.relation.code2011205737-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF NATURAL SCIENCES[S]-
dc.sector.departmentDEPARTMENT OF CHEMISTRY-
dc.identifier.pidhoeil-
Appears in Collections:
COLLEGE OF NATURAL SCIENCES[S](자연과학대학) > CHEMISTRY(화학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE