588 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author박준석-
dc.date.accessioned2017-12-19T05:15:56Z-
dc.date.available2017-12-19T05:15:56Z-
dc.date.issued2016-03-
dc.identifier.citation설비공학 논문집, v. 28, NO 3, Page. 110-114en_US
dc.identifier.issn1229-6422-
dc.identifier.issn2465-7611-
dc.identifier.urihttp://koreascience.or.kr/article/ArticleFullRecord.jsp?cn=SBGHC5_2016_v28n3_110-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/34199-
dc.description.abstractNewly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over 16℃ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452₩/household in Incheon city and from 3,521 to 26,268₩/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.en_US
dc.description.sponsorship본 연구는 2015년도 국토교통과학기술진흥원 연구비 지원에 의한 결과의 일부임(과제번호:15RERP-B082204-02).en_US
dc.language.isoko_KRen_US
dc.publisher대한설비공학회en_US
dc.subject플러쉬아웃en_US
dc.subject실내공기질en_US
dc.subject건물에너지 시뮬레이션en_US
dc.subject난방에너지 비용en_US
dc.subjectFlush-outen_US
dc.subjectIAQen_US
dc.subjectBuilding energy simulationen_US
dc.subjectHeating energy costen_US
dc.title겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구en_US
dc.title.alternativeStudy of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Seasonen_US
dc.typeArticleen_US
dc.relation.no3-
dc.relation.volume28-
dc.identifier.doi10.6110/KJACR.2016.28.3.110-
dc.relation.page110-114-
dc.relation.journal설비공학 논문집-
dc.contributor.googleauthor이기용-
dc.contributor.googleauthor김기한-
dc.contributor.googleauthor박준석-
dc.contributor.googleauthorLee, Ki Yong-
dc.contributor.googleauthorKim, Kee Han-
dc.contributor.googleauthorPark, Jun-Seok-
dc.relation.code2016018736-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjunpark-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE