540 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정재원-
dc.date.accessioned2017-07-26T06:20:54Z-
dc.date.available2017-07-26T06:20:54Z-
dc.date.issued2015-10-
dc.identifier.citation대한건축학회 창립70주년기념대회 및 추계학술발표대회논문집 제35권 제2호(통권 제64집), 2015.10, 413-414en_US
dc.identifier.issn2287-5786-
dc.identifier.urihttp://www.dbpia.co.kr/Article/NODE06524799-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/28034-
dc.description.abstractIn this study, ventilation performance of liquid desiccant in an evaporative-cooling assisted 100% outdoor air system was evaluated. Carbon-dioxide gas was used as a tracer gas to evaluate the ventilation performance. Air change rate (ACR) was considered as a ventilation efficiency index. CO₂ gas was injected in to test room of 81 m³ and concentration decay was measured when ventilating room with LD-IDECOAS and VAV system. Supply air flow rate of two system is set to 1500 CMH and 1200 CMH of return air was used in VAV system. Conquently, it was found that the LD-IDECOAS has better ventilation performance than VAV system.en_US
dc.description.sponsorship이 연구는 2015년도 정부(미래창조과학부)의 재원으로 한국연구재단의 지원을 받아 수행된 연구임.(No. 2015R1A2A1A05001726)en_US
dc.language.isoko_KRen_US
dc.publisher대한건축학회en_US
dc.subject환기en_US
dc.subject추적기체법en_US
dc.subject전 외기 공조시스템en_US
dc.subject시간 당 환기 횟수en_US
dc.subjectVentilationen_US
dc.subjecttracer gas techniqueen_US
dc.subject100% outdoor air systemen_US
dc.subjectair change rateen_US
dc.title제습 증발냉각 기반 전 외기 공조시스템의 환기 성능 평가en_US
dc.title.alternativeVentilation performance evaluation of liquid desiccant in an evaporative-cooling assisted 100% outdoor air systemen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume35-
dc.relation.page281-282-
dc.contributor.googleauthor윤동섭-
dc.contributor.googleauthor이성준-
dc.contributor.googleauthor박준영-
dc.contributor.googleauthor정재원-
dc.contributor.googleauthorYoon, Dong-Seob-
dc.contributor.googleauthorLee, Seong-Joon-
dc.contributor.googleauthorPark, Joon-Young-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles