492 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author이재기-
dc.date.accessioned2017-07-21T02:36:49Z-
dc.date.available2017-07-21T02:36:49Z-
dc.date.issued2015-10-
dc.identifier.citationPHYSICS IN MEDICINE AND BIOLOGY, v. 60, NO 22, Page. 8695-8707en_US
dc.identifier.issn0031-9155-
dc.identifier.issn1361-6560-
dc.identifier.urihttp://iopscience.iop.org/article/10.1088/0031-9155/60/22/8695/meta;jsessionid=4DFB1B7BA9A098B6A821509C4B05E7D4.ip-10-40-1-105-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/27983-
dc.description.abstractThe dose coefficients for the eye lens reported in ICRP 2010 Publication 116 were calculated using both a stylized model and the ICRP-110 reference phantoms, according to the type of radiation, energy, and irradiation geometry. To maintain consistency of lens dose assessment, in the present study we incorporated the ICRP-116 detailed eye model into the converted polygon-mesh (PM) version of the ICRP-110 reference phantoms. After the incorporation, the dose coefficients for the eye lens were calculated and compared with those of the ICRP-116 data. The results showed generally a good agreement between the newly calculated lens dose coefficients and the values of ICRP 2010 Publication 116. Significant differences were found for some irradiation cases due mainly to the use of different types of phantoms. Considering that the PM version of the ICRP-110 reference phantoms preserve the original topology of the ICRP-110 reference phantoms, it is believed that the PM version phantoms, along with the detailed eye model, provide more reliable and consistent dose coefficients for the eye lens.en_US
dc.description.sponsorshipThis project was supported by Nuclear Safety and Security Commission (NSSC) through Korea Radiation Safety Foundation (KORSAFe) and also by Ministry of Science, ICT and Future Planning through the National Research Foundation of Korea (Project No.: 2011-0025496, 2012-K001146, 1403012). Two of the authors were supported by the Global PhD Fellowship program (Project No.: 2011-0007318, 2011-0030970).en_US
dc.language.isoenen_US
dc.publisherIOP PUBLISHING LTDen_US
dc.subjectICRP reference phantomen_US
dc.subjectdetailed eye modelen_US
dc.subjectpolygon-mesh phantomen_US
dc.subjectlens dose coefficientsen_US
dc.subjectMonte Carloen_US
dc.titleIncorporation of detailed eye model into polygon-mesh versions of ICRP-110 reference phantomsen_US
dc.typeArticleen_US
dc.relation.no22-
dc.relation.volume60-
dc.identifier.doi10.1088/0031-9155/60/22/8695-
dc.relation.page8695-8707-
dc.relation.journalPHYSICS IN MEDICINE AND BIOLOGY-
dc.contributor.googleauthorNguyen, Thang Tat-
dc.contributor.googleauthorYeom, Yeon Soo-
dc.contributor.googleauthorKim, Han Sung-
dc.contributor.googleauthorWang, Zhao Jun-
dc.contributor.googleauthorHan, Min Cheol-
dc.contributor.googleauthorKim, Chan Hyeong-
dc.contributor.googleauthorLee, Jai Ki-
dc.contributor.googleauthorZankl, Maria-
dc.contributor.googleauthorPetoussi-Henss, Nina-
dc.contributor.googleauthorBolch, Wesley E-
dc.relation.code2015002067-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidjakilee-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE