Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최재훈 | - |
dc.date.accessioned | 2017-03-31T05:08:35Z | - |
dc.date.available | 2017-03-31T05:08:35Z | - |
dc.date.issued | 2015-07 | - |
dc.identifier.citation | IEICE TRANSACTIONS ON COMMUNICATIONS, v. E98B, NO 7, Page. 1323-1332 | en_US |
dc.identifier.issn | 1745-1345 | - |
dc.identifier.uri | http://search.ieice.org/bin/summary.php?id=e98-b_7_1323 | - |
dc.identifier.uri | http://hdl.handle.net/20.500.11754/26486 | - |
dc.description.abstract | New target specific absorption rate (SAR) values, calculated using a proposed reference dipole antenna and the reference flat phantom, are presented for an SAR validation test at 150 MHz. The reference flat phantom recommended by the International Electrotechnical Commission (IEC) standard for 150MHz requires a significant amount of liquid owing to its large size. We conduct a numerical analysis in order to reduce the size of the flat phantom. The optimum size of the flat phantom is 780 (L-1) x 540 (W) x 200 (H) mm(3), which is approximately a 64% reduction in volume compared to the reference flat phantom. The length of the reference dipole antenna required for the optimized flat phantom (extrapolated from the reference values at 300 MHz) becomes 760 mm. The calculated and measured return losses (S-11) of the antenna at 150MHz are 24.1 dB and 22 dB, respectively. The calculated and measured results for the return loss of the dipole antenna agree well and satisfy the IEC standard (˃ 20 dB). The target SAR values derived from the numerical analysis are 1.08W/kg for 1 g of tissue and 0.77W/kg for 10 g of tissue for an SAR validation test at 150 MHz. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IEICE-INST ELECTRONICS INFORMATION COMMUNICATIONS ENG | en_US |
dc.subject | SAR measurement | en_US |
dc.subject | validation test | en_US |
dc.subject | reference dipole antenna | en_US |
dc.subject | flat phantom | en_US |
dc.subject | target SAR value | en_US |
dc.title | New Numerical Target SAR Values and an Optimized Flat Phantom for SAR Validation Tests in the 150 MHz Band | en_US |
dc.type | Article | en_US |
dc.relation.no | 7 | - |
dc.relation.volume | E98B | - |
dc.identifier.doi | 10.1587/transcom.E98.B.1323 | - |
dc.relation.page | 1323-1332 | - |
dc.relation.journal | IEICE TRANSACTIONS ON COMMUNICATIONS | - |
dc.contributor.googleauthor | Choi, Dong-Geun | - |
dc.contributor.googleauthor | Kim, Ki-Hwea | - |
dc.contributor.googleauthor | Choi, Jaehoon | - |
dc.relation.code | 2015002536 | - |
dc.sector.campus | S | - |
dc.sector.daehak | COLLEGE OF ENGINEERING[S] | - |
dc.sector.department | DEPARTMENT OF ELECTRONIC ENGINEERING | - |
dc.identifier.pid | choijh | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.