329 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author정진욱-
dc.date.accessioned2017-02-09T02:45:24Z-
dc.date.available2017-02-09T02:45:24Z-
dc.date.issued2015-06-
dc.identifier.citationJOURNAL OF APPLIED PHYSICS, v. 117, NO 24, Page. 1-5en_US
dc.identifier.issn0021-8979-
dc.identifier.issn1089-7550-
dc.identifier.urihttp://aip.scitation.org/doi/abs/10.1063/1.4922861-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/25414-
dc.description.abstractA phase delay harmonic analysis method (PDHAM) with high-time resolution is proposed to measure the plasma parameters of the pulsed plasmas. The PDHAM, which is based on the floating harmonic method, applies the phase delayed voltages to a probe tip, and obtains each of the currents in the phase-domain at a given time. The time resolution of this method is 0.8 mu s, and the total measurement is done within 2 s in the case of a pulsed plasma with a frequency of 1 kHz. The measurement result of the plasma parameters was compared with a conventional Langmuir probe using a boxcar mode, and shows good agreements. Because this PDHAM can measure the plasma parameters even in the processing discharges, it is expected to be usefully applied to plasma diagnostics for pulsed processing plasmas. (C) 2015 AIP Publishing LLC.en_US
dc.description.sponsorshipThis research was supported by the Industrial Strategic Technology Development Program (10041681), the Converging Research Center Program(NRF-2014M3C1A8053701), and the National R&D Program(NRF-2014M1A7A1A03045185).en_US
dc.language.isoenen_US
dc.publisherAMER INST PHYSICSen_US
dc.subjectINDUCTIVELY-COUPLED PLASMAen_US
dc.subjectLANGMUIR PROBEen_US
dc.subjectELECTRON-TEMPERATUREen_US
dc.subjectDISCHARGESen_US
dc.subjectPOWERen_US
dc.subjectDIAGNOSTICSen_US
dc.subjectDEPOSITIONen_US
dc.subjectDENSITYen_US
dc.subjectSILICONen_US
dc.subjectDAMAGEen_US
dc.titlePulsed plasma measurement method using harmonic analysisen_US
dc.typeArticleen_US
dc.relation.no24-
dc.relation.volume117-
dc.identifier.doi10.1063/1.4922861-
dc.relation.page1-5-
dc.relation.journalJOURNAL OF APPLIED PHYSICS-
dc.contributor.googleauthorKim, Yu-Sin-
dc.contributor.googleauthorKim, Dong-Hwan-
dc.contributor.googleauthorLee, Hyo-Chang-
dc.contributor.googleauthorChung, Chin-Wook-
dc.relation.code2015003356-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF ELECTRICAL AND BIOMEDICAL ENGINEERING-
dc.identifier.pidjoykang-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ELECTRICAL AND BIOMEDICAL ENGINEERING(전기·생체공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE