454 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author최동호-
dc.date.accessioned2017-01-11T04:38:46Z-
dc.date.available2017-01-11T04:38:46Z-
dc.date.issued2015-06-
dc.identifier.citationINTERNATIONAL JOURNAL OF STEEL STRUCTURES, v. 15, NO 2, Page. 285-297en_US
dc.identifier.issn1598-2351-
dc.identifier.issn2093-6311-
dc.identifier.urihttp://link.springer.com/article/10.1007%2Fs13296-015-6003-8-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/25051-
dc.description.abstractThe evaluation of the effective length factor (K-factor) of columns based on the system buckling approach is a convenient tool in the stability design of multi-story frames. This method is superior to other analytical approaches, such as isolated subassembly and story-based approaches, in that inter-column and inter-story interactions are inherently taken into account. In this study, in order to investigate the effect of nonconservative forces on buckling loads and K-factors for the single- and multistory framed structures, the system buckling approach is presented. For this purpose, the finite element model, based on the Hamilton's principle, is formulated for the stability analysis of framed structures subjected to nonconservative forces. In numerical examples, buckling loads and K-factors for single- and multi-story frames subjected to conservative or nonconservative forces are evaluated and compared with those obtained by other researchers. Especially the effect of the stiffness ratio of girder to column on K-factors is investigated for nonconservative systems.en_US
dc.description.sponsorshipThis research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology (2012 R1A1A2007054). The authors wish to express their gratitude for the financial support.en_US
dc.language.isoenen_US
dc.publisherKOREAN SOC STEEL CONSTRUCTION-KSSCen_US
dc.subjectsystem bucklingen_US
dc.subjecteffective lengthen_US
dc.subjectmulti-story frameen_US
dc.subjecttangential forceen_US
dc.titleSystem buckling analysis for multi-story frames subjected to nonconservative forcesen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume15-
dc.identifier.doi10.1007/s13296-015-6003-8-
dc.relation.page285-297-
dc.relation.journalINTERNATIONAL JOURNAL OF STEEL STRUCTURES-
dc.contributor.googleauthorKim, Nam-Il-
dc.contributor.googleauthorChoi, Dong-Ho-
dc.relation.code2015007772-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidsamga-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE