75 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김정현-
dc.date.accessioned2024-06-07T01:45:47Z-
dc.date.available2024-06-07T01:45:47Z-
dc.date.issued2023-08-31-
dc.identifier.citationIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, v. 17, no 5, page. 1125-1134en_US
dc.identifier.issn1932-4545en_US
dc.identifier.issn1940-9990en_US
dc.identifier.urihttps://ieeexplore.ieee.org/document/10236593en_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/190530-
dc.description.abstractIn this article, a 4-MHz full-bridge inverter system for an electrosurgical generator (ESG) is presented with zero-voltage switching (ZVS) turn-on over a wide load impedance range based on wideband gap material gallium nitride (GaN) technology. The proposed resonant circuit is used for impedance matching and limits the current when the load is short state while performing ZVS over a wide load impedance range. It also ensures high power performance at high frequencies for electric surgery. The implementation methods of the GaN switch at 4 MHz with high output performance are guided by the low inductance from the gate-driver output to the switch gate node and the effective heating management structure of the GaN-based inverter. The proposed generator achieved a maximum output power of 99 W to the load and a maximum overall efficiency of 89% with overcurrent of ˂3 A at short state of the load. The ESG can generate constant output power of 20, 50, 70 W through mode control of 2, 5, and 7 s. The overcurrent Moreover, the proposed generator is tested on porcine tissue samples to verify its effectiveness as an ESG.en_US
dc.languageen_USen_US
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INCen_US
dc.relation.ispartofseriesv. 17, no 5;1125-1134-
dc.subjectElectrosurgical generator (ESG)en_US
dc.subjectGaN switchen_US
dc.subjecthigh efficiencyen_US
dc.subjecthigh-frequency full-bridge inverteren_US
dc.subjectresonant filteren_US
dc.subjectwide load impedance rangeen_US
dc.subjectzero-voltage switching (ZVS)en_US
dc.titleGaN-Based 4-MHz Full-Bridge Electrosurgical Generator Using Zero-Voltage Switching Over Wide Load Impedance Rangeen_US
dc.typeArticleen_US
dc.relation.no5-
dc.relation.volume17-
dc.identifier.doi10.1109/TBCAS.2023.3310880en_US
dc.relation.page1125-1134-
dc.relation.journalIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS-
dc.contributor.googleauthorHwang, Sungwoon-
dc.contributor.googleauthorLee, Seokmin-
dc.contributor.googleauthorYoon, Byeongcheol-
dc.contributor.googleauthorJeong, Byongchang-
dc.contributor.googleauthorKim, Jongchan-
dc.contributor.googleauthorKim, Sungmin-
dc.contributor.googleauthorKim, Junghyun-
dc.relation.code2023034572-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentSCHOOL OF ELECTRICAL ENGINEERING-
dc.identifier.pidjunhkim-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ELECTRICAL ENGINEERING(전자공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE