dc.identifier.citationSensors and Actuators, B: Chemical, v. 147, NO. 1, Page. 55-60-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0925400510002376?via%3Dihuben_US
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/183767-
dc.description.abstractSix composite sensors were prepared by casting a solution of different polymers and conductive carbon black nanoparticles on a glass substrate with two comb-shape Au electrodes. The chemoresistive response and background noise level were measured as a function of concentration upon exposure to various breath biomarker compounds: acetic acid, toluene, ethanol, acetone, n-pentane, and isoprene. All sensors exhibited a good linear response with respect to concentration, suggesting a typical volumetric transduction mechanism. Limit-of-detection (LOD) values were determined by an extrapolation of the linear relationship and were found to be in the range of 80 ppb to 240 ppm, demonstrating the potential of highly sensitive detection for the biomarkers. The LOD variation can be roughly interpreted in terms of the difference in boiling temperature of an analyte in a physisorption-based model; the higher boiling temperature results in a lower LOD due to a strong tendency toward condensation. The LOD values were observed to become two or three orders of magnitude smaller by exploiting specific chemical interactions between the polymers used and the analyte. (c) 2010 Elsevier B.V. All rights reserved.-
dc.description.sponsorshipThis research was supported by the National Research Founda-tion of Korea (NRF) funded by the Ministry of Education, Science and Technology (No. 2009-0083917).-
dc.languageen-
dc.publisherElsevier BV-
dc.subjectCarbon black-polymer composite-
dc.subjectGas sensor-
dc.subjectLimit-of-detection-
dc.subjectElectronic nose system-
dc.titleEvaluation of the limit-of-detection capability of carbon black-polymer composite sensors for volatile breath biomarkers-
dc.typeArticle-
dc.relation.no1-
dc.relation.volume147-
dc.identifier.doi10.1016/j.snb.2010.03.025-
dc.relation.page55-60-
dc.relation.journalSensors and Actuators, B: Chemical-
dc.contributor.googleauthorKang, Nae Kyoung-
dc.contributor.googleauthorJun, Tae Sun-
dc.contributor.googleauthorLa, Duc-Duong-
dc.contributor.googleauthorOh, Je Hoon-
dc.contributor.googleauthorCho, Yong Woo-
dc.contributor.googleauthorKim, Yong Shin-
dc.sector.campusE-
dc.sector.daehak공학대학-
dc.sector.department재료화학공학과-
dc.identifier.pidywcho7-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MATERIALS SCIENCE AND CHEMICAL ENGINEERING(재료화학공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE